SVS-VISTEK
Feature-Set
78
Example:
Values to set
Interval 0
Interval 1
Interval 2
Sequencer
Interval
1.000.000 µs
(1s)
1.000.000 µs
(1s)
1.000.000 µs
(1s)
Exposure Start
220.000 µs
875.000 µs
190.000 µs
Exposure Stop
700.000 µs
125.000 µs
720.000 µs
Strobe Start
110.000 µs
125.000 µs
350.000 µs
Strobe Stop
875.000 µs
875.000 µs
875.000 µs
PWM
Frequency
4 Hz
4 Hz
4 Hz
PWM Line 0
100
0
80
PWM Line 1
20
50
0
PWM Line 2
0
100
30
PWM Line 3
-
-
-
Trigger set to negative slope
Use higher frequencies
Figure 51: three sequencer intervals