![SVS-Vistek eco4050 Manual Download Page 82](http://html.mh-extra.com/html/svs-vistek/eco4050/eco4050_manual_1410868082.webp)
SVS-VISTEK
Feature-Set
82
OR
If neither input is high, a low pulse_out (0) results.
Combine trigger input one and two.
A
B
Y = A v B
0
0
0
0
1
1
1
0
1
1
1
1
NOR
No trigger input – one nor two – results in a high or a low level
pulse_out.
Invert both trigger inputs. By inverting the resulting pulse_out you will get
the NOR I pulse
A
B
Y = A
⊽
B
NOR
Y = A
∨
B
NOR i
0
0
1
0
0
1
0
1
1
0
0
1
1
1
0
1
7.3.6
Serial data interfaces
(ANSI EIA/) TIA-232-F
RS-232 and RS-422 (from EIA, read as Radio Sector or commonly as
Recommended Standard) are technical standards to specify electrical
characteristics of digital signaling circuits.