![SVS-Vistek eco4050 Manual Download Page 86](http://html.mh-extra.com/html/svs-vistek/eco4050/eco4050_manual_1410868086.webp)
SVS-VISTEK
Feature-Set
86
Therefor the signal will not be accepted till it lasts at least a certain time.
Use the IO Assignment tool to place and enable the debouncer module
in between the “trigger” (schmitt trigger) and the input source (e.g.: line
1).
DebouncDuration register can be set in multiples of 15ns (implement of
system clock). E.g. 66 666 ≈ 1 ms
Figure 58: debouncer between the trigger source and trigger
The Debouncer module
Figure 59: Illustration of the debouncer module