29
[Fig. IV-2-9] One Detector Selection in SLM
[Fig. IV-2-10] Activated Window for One
Detector in SLM
You can measure acceleration, velocity, displacement with various physical quantities at the same
time in the vibration level meter. The various quantities are RMS(Root-Mean-Square), Peak, Peak To
Peak, Max and Min.
[Fig. IV-2-11] Setting with various units in
VLM
[Fig. IV-2-12] Display with various units in
VLM
You can change unit with
m
,
mm
,
m
μ
,
g
. For example, you can set a unit of acceleration to
2
/
m s
,
2
/
cm s
,
2
/
mm s
,
2
/
μ
m s
,
g
and display vibration levels with linear scale or logarithms
scale(dB:Decibel). The reference acceleration of decibel unit is
6
2
10
/
m s
−
. Of course, you can
choose
5
2
10
/
m s
−
in the [Acc. Decibel Ref:] of [File >>Transducer Calibration…] tap. This function
works when you select accelerator in the transducer. The references of the decibel calculation are
listed in the <Table IV-2-1>.