XLINK 500/100 Operations & Maintenance Manual page # 129
•
Measurement failure
•
Any error
The following settings control the events that cause notifications:
Notify On Bootup
Notify On Recording
Notify On Tx Fail
Notify On Alarms
Notify On SDI12 failure
Notify On Measurement error
Notify On Any error
Please note that there is some overlap between the error notifications.
Only one error notification is sent at a time, and only one error notification is sent per day. This
means that additional errors may be not be reported.
The cell modem will be kept on for 15 minutes after a notification is issued, allowing the
customer to send a follow up SMS to get more information. For example, replying to a
notification SMS with the text “!ERROR” will cause the station to reply with an SMS containing
the list of errors.
All notifications have the same format. Up to two SMS are sent per notification; please note that
not all the data may fit. Here are some examples:
The station name is on the first line of the message.
The current station time is on the second line.
The next line contains the event that caused the notification, e.g.,
“Alarm In”,
“Error”.
If appropriate, error details are on the next line.
The most recent measurements are listed next, along with the alarm state for each. E.g.
“TEMP 25.5 C”
At the end of the SMS are the number of tra
nsmissions made today, e.g. “TX3 today:
good 31, bad 3
”
Below is an example of a bootup notification. There is no measurement data because the system
had no time to make a reading.
Sutron XLink 500 testbase
2017/11/07 15:25:54
Reset Soft
TX3 today: good 0, bad 0
Here is an alarm notification: