XLINK 500/100 Operations & Maintenance Manual page # 103
10.
Telemetry Setup
XLink features a built-in modem which is used for telemetry. XLink will collect sensor data and
later transmit that data to a remote destination. The telemetry setup manages the transmission
of data.
Just as there are multiple measurements that may be setup, there are multiple telemetry setups.
Each setup is independent of another. Multiple telemetry setups are needed in order to transmit
data to different servers over the cellular network. Multiple setups are needed to allow for both
scheduled and alarm transmissions.
Each telemetry setup is configured and enabled separately. If no telemetry setups are enabled,
the system will show an error on the dashboard.
We use the shorthand name Tx to mean transmission. ReTx means retransmission.
Please note that the transmission data content is governed by measurement setup. Please see
the section
10.1.1.
Enable
This is the master switch for enabling the telemetry setup.
For Scheduled transmissions, the Enable setting turns on scheduled (sometimes called self-
timed) transmissions. If this setting is enabled, the system will periodically deliver sensor data to
the designated destination. If disabled, the system will not initiate any scheduled transmissions.
For Alarm transmissions, the Enable setting determines whether a transmission is sent when the
system is affected by measurement alarms.
10.1.2.
Radio Type
Which radio is to be used for the telemetry? Available radios may include Iridium and Cell,
depending on the radio installed in the station.
10.1.3.
Kind
Several different transmission kinds may be setup:
Scheduled
Alarm
Please read on for a description of transmission kinds.
10.1.4.
Scheduled Transmissions
Scheduled transmissions happen on a periodic basis controlled by the Scheduled Time and
Scheduled Interval settings. If the Interval is set to one hour, there will be 24 transmissions per
day, every day.
When the station should make a transmission depends on the transmission schedule. The time
is computed based upon these settings:
Scheduled Time
Scheduled Interval