  Safety instructions 

Safety instructions 

Observe the following instructions to use the product safely and prevent any risk of injury or property damage. 
 

Warning

 

Noncompliance of instructions could lead to serious injury or death. 

Installation 

Do not install the product in a place with direct sunlight, moisture, dust, or soot. 

 

A fire or electric shock may occur. 

Do not install the product in a place with heat from an electric heater. 

 

A fire or electric shock may occur due to overheating. 

Install the product in a dry place. 

 

Otherwise, a product damage or electric shock may occur due to moisture. 

Install the product in a place with no electromagnetic interference. 

 

Otherwise, a product damage or electric shock may occur. 

The user should not install or repair the product independently. 

 

A fire, electric shock, or personal injury may occur.   

 

If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be 

provided. 

Operation 

Do not allow liquids such as water, beverages, or chemicals get into the product.   

 

A fire, electric shock, or product damage may occur. 

 
 

Caution

 

Noncompliance of instructions could lead to minor injury or product damage.   

Installation

 

Do not install the power supply cable in a place where people pass by. 

 

Product damage or physical injury may occur.   

Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker. 

 

A product failure may occur. 

Use only a power supply adaptor of D.C 12 V and 500 mA or higher. 

 

If the proper power is not used, the product may not operate normally. 

If installing the product outside where the product is completely exposed, it is recommended to install the product together with 
the enclosure. 
Use a separate power supply for Secure I/O 2, electric lock and BioStation A2 respectively. 

 

If connecting and using the power supply to these devices together, the devices may malfunction. 

Keep at least 10cm distances between the devices when install multiple devices.   

 

Otherwise, RF performance is affect to the other device, the devices may not operate normally.   

 
 

 

 

Summary of Contents for BioStation A2

Page 1: ...English Version 1 00 BioStation A2 INSTALLATION GUIDE www supremainc com EN 101 00 BSA2 V1 00A...

Page 2: ...bracket and the product 10 Power supply connection 11 Network connection 11 TCP IP 11 TTL input and output connection 12 Relay connection 13 Fail Safe Lock 13 Fail Secure Lock 13 Automatic door connec...

Page 3: ...vice will not be provided Operation Do not allowliquids suchas water beverages or chemicals get intothe product A fire electric shock or product damage may occur Caution Noncompliance of instructions...

Page 4: ...rty hand or foreign substances Deterioration in fingerprint authentication performance and a product failure may occur Whencleaningthe product wipe the product with a soft and dryclothand no water ben...

Page 5: ...s may vary according to the installationenvironment Note BioStation A2 Wall bracket Fixing screw 4 EA PVC anchor 4 EA Diode 1 EA Connection cable 2 pins 1 EA 3 pins 2 EA 4 pins 4 EA Ferrite core 1 EA...

Page 6: ...or of the LED lamp Fingerprint authenticationunit Part to scan the fingerprint for entrance RF card authentication unit Part to scan the card for entrance USBmemory slot Connects USB memory Mini USB c...

Page 7: ...Relay 0 1 3 pins Connect the relay cable Power supply 2 pins Connect the power supply cable Ethernet Connect the Ethernet cable Wiegand input 4 pins Connect theWiegand input and output cable Wiegand o...

Page 8: ...Pin Name Color 1 RLY NO White 2 RLY COM Blue 3 RLY NC Orange RS 485 Pin Name Color 1 485TRXP Blue 2 485TRXN Yellow 3 485 GND Black 4 SH GND Gray TTL input Pin Name Color 1 TTL IN0 Red 2 TTL IN1 Yellow...

Page 9: ...yed after a beep sound scan the fingerprint of the registered finger again scan the fingerprint of a finger to be registered twice Cautions for enrolling afingerprint When a fingerprint is recognized...

Page 10: ...installed If installing BioStation A2 on a concrete wall drill holes insert PVC anchors and fix them with fixing screws Keep at least 10cm distances between the devices when install multiple devices O...

Page 11: ...han the total power consumption required for the terminal and another device Use a separate power supply for Secure I O 2 the electric lock and the product respectively If connecting and using the pow...

Page 12: ...MDI MDIX function so that it can be connected to a PC directly using a normal straight type CAT 5 cable or a cross cable TTL input and output connection Door sensor BioStation A2 1 TTL IN0 Red 2 TTL I...

Page 13: ...for BioStationA2 and the door lock Fail Secure Lock In order to use the Fail Secure Lock connect N O relay as shown in the figure below There is normally no current flowing through the relay for the...

Page 14: ...Installation 14 Automatic door connection BioStation A2 Automatic door control device Detection sensor 1 RLY NO White 2 RLY COM Blue Door button Door lock...

Page 15: ...on method number of users and number of devices Also note that the number of slave devices affects the fingerprint authentication speed Amaster device can control 31slave devices The bandwidth of RS48...

Page 16: ...slave devices with the RS485 cable The slave devices are used as dummy readers and authentication is performed in the master device If Xpass is connected to the master device only card authenticationc...

Page 17: ...0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Gray RFID reader BioStation A2 Use as a Wiegand input device Use as a Wiegand output device Cable shield optional Cable shield optional BioStation A2 1 WG...

Page 18: ...Fingerprint Image dimension 272 x 320 pixels Image bit depth 8bit 256 grayscale Resolution 500 dpi Template SUPREMA ISO 19794 2 ANSI 378 Extractor Matcher MINEX certified and compliant LFD Supported C...

Page 19: ...Product specifications 19 Dimensions Unit mm...

Page 20: ...r relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Con...

Page 21: ...panies and distributors of Suprema do not accept responsibility nor will they reimburse for all related direct and indirect expenses or expenditure including attorney fees even if the consumer has dis...

Page 22: ...www supremainc com www supremainc com...

Reviews: