suprema BioStation A2 Installation Manual Download Page 9

  Introduction 

How to enroll a fingerprint 

In order to improve the fingerprint authentication rate, register the fingerprint correctly. BioStation A2 can recognize a fingerprint even if 

the angle and position of a user's fingerprint input change. If you register the fingerprint with attention to the following matters, the 
authentication rate can be improved. 

Selecting a finger for fingerprint input 

 

In preparation for the case that the fingerprint of a specific finger cannot be used, for example if 

the user is lifting a load with one hand or a finger gets hurt, up to 10 fingerprints for each user can 

be registered.   

 

In the case of a user whose fingerprint cannot be recognized well, the authentication rate can be 

improved by enrolling the same finger twice repeatedly.   

 

If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint. 

 

It is recommended to use the index finger or the middle finger when scanning the fingerprint. The 

authentication rate can be reduced if it is difficult to place another finger at the center of 

fingerprint sensor accurately. 

 

Fingerprint enroll method 

When a message saying “Scan the fingerprint.”

 

is displayed on the LCD screen for enrolling the fingerprint, place the finger with the 

fingerprint to be registered on the fingerprint authentication unit and press the finger gently for better authentication.   

 

When the re-input screen is displayed after a beep sound, scan the fingerprint of the registered finger again (scan the fingerprint of a 

finger to be registered twice). 

 

Cautions for enrolling a fingerprint 

When a fingerprint is recognized, it is compared with the initially registered fingerprint, so the initial fingerprint enroll is the most important. Pay 

attention to the following matters when enrolling the fingerprint. 

 

Place the finger deep enough to contact with the sensor completely. 

 

Place the center of the fingerprint in the center of the sensor.   

 

If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.   

 

Scan the fingerprint correctly without moving according to the instruction on the screen.   

 

If you make the finger upright so that the contact area with the sensor has decreased or the angle of finger has warped, fingerprint authentication 
may not be performed.   

 

When the fingerprint recognition fails 

BioStation A2 can recognize a fingerprint regardless of a change of season or finger condition. However, the authentication rate may vary according to 

the external environment or fingerprint input method.   

If the fingerprint authentication cannot be done smoothly, it is recommended to take the following measures.   

 

If the finger is smeared with water or sweat, dry off the finger and then scan the finger. 

 

If the finger is too dry, blow your breath on the fingertips and then scan the finger. 

 

If the finger has a cut, register the fingerprint of another finger. 

 

The initially registered fingerprint often may have not been scanned correctly, so register the fingerprint again according to ‘

Cautions for enrolling 

a fingerprint

’.  

 

 

Note 

Summary of Contents for BioStation A2

Page 1: ...English Version 1 00 BioStation A2 INSTALLATION GUIDE www supremainc com EN 101 00 BSA2 V1 00A...

Page 2: ...bracket and the product 10 Power supply connection 11 Network connection 11 TCP IP 11 TTL input and output connection 12 Relay connection 13 Fail Safe Lock 13 Fail Secure Lock 13 Automatic door connec...

Page 3: ...vice will not be provided Operation Do not allowliquids suchas water beverages or chemicals get intothe product A fire electric shock or product damage may occur Caution Noncompliance of instructions...

Page 4: ...rty hand or foreign substances Deterioration in fingerprint authentication performance and a product failure may occur Whencleaningthe product wipe the product with a soft and dryclothand no water ben...

Page 5: ...s may vary according to the installationenvironment Note BioStation A2 Wall bracket Fixing screw 4 EA PVC anchor 4 EA Diode 1 EA Connection cable 2 pins 1 EA 3 pins 2 EA 4 pins 4 EA Ferrite core 1 EA...

Page 6: ...or of the LED lamp Fingerprint authenticationunit Part to scan the fingerprint for entrance RF card authentication unit Part to scan the card for entrance USBmemory slot Connects USB memory Mini USB c...

Page 7: ...Relay 0 1 3 pins Connect the relay cable Power supply 2 pins Connect the power supply cable Ethernet Connect the Ethernet cable Wiegand input 4 pins Connect theWiegand input and output cable Wiegand o...

Page 8: ...Pin Name Color 1 RLY NO White 2 RLY COM Blue 3 RLY NC Orange RS 485 Pin Name Color 1 485TRXP Blue 2 485TRXN Yellow 3 485 GND Black 4 SH GND Gray TTL input Pin Name Color 1 TTL IN0 Red 2 TTL IN1 Yellow...

Page 9: ...yed after a beep sound scan the fingerprint of the registered finger again scan the fingerprint of a finger to be registered twice Cautions for enrolling afingerprint When a fingerprint is recognized...

Page 10: ...installed If installing BioStation A2 on a concrete wall drill holes insert PVC anchors and fix them with fixing screws Keep at least 10cm distances between the devices when install multiple devices O...

Page 11: ...han the total power consumption required for the terminal and another device Use a separate power supply for Secure I O 2 the electric lock and the product respectively If connecting and using the pow...

Page 12: ...MDI MDIX function so that it can be connected to a PC directly using a normal straight type CAT 5 cable or a cross cable TTL input and output connection Door sensor BioStation A2 1 TTL IN0 Red 2 TTL I...

Page 13: ...for BioStationA2 and the door lock Fail Secure Lock In order to use the Fail Secure Lock connect N O relay as shown in the figure below There is normally no current flowing through the relay for the...

Page 14: ...Installation 14 Automatic door connection BioStation A2 Automatic door control device Detection sensor 1 RLY NO White 2 RLY COM Blue Door button Door lock...

Page 15: ...on method number of users and number of devices Also note that the number of slave devices affects the fingerprint authentication speed Amaster device can control 31slave devices The bandwidth of RS48...

Page 16: ...slave devices with the RS485 cable The slave devices are used as dummy readers and authentication is performed in the master device If Xpass is connected to the master device only card authenticationc...

Page 17: ...0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Gray RFID reader BioStation A2 Use as a Wiegand input device Use as a Wiegand output device Cable shield optional Cable shield optional BioStation A2 1 WG...

Page 18: ...Fingerprint Image dimension 272 x 320 pixels Image bit depth 8bit 256 grayscale Resolution 500 dpi Template SUPREMA ISO 19794 2 ANSI 378 Extractor Matcher MINEX certified and compliant LFD Supported C...

Page 19: ...Product specifications 19 Dimensions Unit mm...

Page 20: ...r relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Con...

Page 21: ...panies and distributors of Suprema do not accept responsibility nor will they reimburse for all related direct and indirect expenses or expenditure including attorney fees even if the consumer has dis...

Page 22: ...www supremainc com www supremainc com...

Reviews: