Connecting as a standalone
BioStation A2 can be connected to the door lock, door button, and door sensor directly without connecting a separate I/O device.
•
BioStation A2 can be used as a multi-door controller with the slave devices with the RS485 cable. The slave devices are used as dummy readers and
authentication is performed in the master device.
•
If Xpass is connected to the master device, only card authentication can be used.
•
The maximum number of slave devices available to connect varies according to the authentication method, number of users, and number of
devices. Also note that the number of slave devices affects the fingerprint authentication speed.
•
A master device can control 31 slave devices. The bandwidth of RS485 allows for up to 7 fingerprint authentication devices to be connected.
•
For more information, contact the Suprema technical support team ([email protected]).
Note
BioStation A2
PC
Door button
Door sensor
or
Cable shield (optional)
TTL
TTL connection
1 - TTL IN0
Red
2 - TTL IN1
Yellow
3 - TTL GND
Black
4 - SH GND
Gray
Relay connection
1 - RLY NO
White
2 - RLY COM
Blue
3 - RLY NC
Orange
Hub
Fail Secure Lock
Fail Safe Lock
DC power
DC power
Dead bolt /
Door strike
Power supply connection
1 - PWR +VDC
Red (white stripe)
2 - PWR GND
Black (white stripe)
Relay