Product specifications
18
Product specifications
Category
Feature
Specification
Credential
Biometric
Fingerprint
RF Option
2.4 GHz, 13.56MHz Mifare/DesFire/DesFire EV1/Felica/NFC,
13.56MHz iClass SE
RF read range
*
MIFARE: 50 mm, DESFire: 50 mm, Felica: 30 mm, ISO15693: 50 mm
LFD
Supported
General
CPU
1.0 GHz Quad Core
Memory
8GB Flash + 1GB RAM
LCD type
5” color TFT touch
LCD resolution
480 x 854
LED
Multiple colors
Sound
24 bit/Voice DSP (echo cancel)
Operating temperature
-20°C - 50°C
Storage temperature
-40°C - 70°C
Operating humidity
0% - 80%, non-condensing
Storage humidity
0% - 90%, non-condensing
Camera type
CMOS 2M pixels
Camera resolution
1600 x 1200
Camera angle
Diagonal 122°, Horizontal 64.7°, Vertical 103.3°
Dimension (W x H x D)
155 mm x 155 mm x 40 mm
Weight
Device: 440g
Bracket: 89g (Including washer and bolt)
Certificates
CE, FCC, KC, RoHS, REACH, WEEE
Fingerprint
Image dimension
272 x 320 pixels
Image bit depth
8bit, 256 grayscale
Resolution
500 dpi
Template
SUPREMA / ISO 19794-2 / ANSI 378
Extractor / Matcher
MINEX certified and compliant
LFD
Supported
Capacity
Max. User (1:1)
500,000
Max. User (1:N)
100,000
Max. Template (1:1)
1,000,000
Max. Template (1:N)
200,000
Max. Text Log
5,000,000
Max. Image Log
50,000
Interface
Wi-Fi
Supported
Ethernet
Supported (10/100 Mbps, auto MDI/MDI-X)
RS-485
1ch Host or Slave (Selectable)
Wiegand
1ch Input, 1ch Output
TTL input
1ch Input
Relay
2 Relay
USB
USB 2.0 (Host)
SD Card
microSD card (Supports up to 32GB)
PoE
Supported (IEEE 802.3af compliant)
Tamper
Supported
Electrical
Power
Voltage: 12VDC
Current: Max. 850 mA
Switch input V
IH
Min.: 3V
Max.: 5V
Switch input V
IL
Max.: 1V
Switch Pull-up resistance
4.7kΩ (The input pots are pulled up with 4.7kΩ.)
Wiegand output V
OH
More than 4.8V
Wiegand output V
OL
Less than 0.2 V
Wiegand output Pull-up
resistance
Internally pulled up with 1 kΩ
Relay
Voltage: Max. 30VDC
Current: Max. 1A
* RF read range will vary depending on installation environment.