33
register(decimal)
format
Dynamic variable
1
00
Measurement value
of channel 1
Float
Read
only
2
02
Measurement value
of channel 2
Float
Read
only
……
……
……
Float
Read
only
n
2
(
n-1
)
Measurement value
of channel n
Float
Read
only
n
:
Number of channels
……
……
……
Float
Read
only
11
20
Measurement value
of channel 11
Float
Read
only
12
22
Measurement value
of channel 12
Float
Read
only
13
120
Output state of
contacts.
Long
Read
only
No.0
~
11 bits represent
the output states for
No.1
~
12 contacts, 0:
disconnect, 1: close.
Table2:0x03 Maintaining register address table that read command corresponds to 0x10
write command.
SN
Input
register
address
(decimal)
Name of parameter
Data
format
Type
Remark
Model of instrument
1
0
Model
of
instrument
Char
Read only
Paperless recorder 0x62
Configuration parameter of instrument
1
1
Language selection
Char
Read-write 0:Chinese 1:English
After the upper computer
modifies the display language,
the instrument needs to power
off and then power on again.
2
2
Reservation
Char