2-5 Checking the Serverboard Setup
After setting up the the system, you will need to open the unit to make sure the
serverboard is properly installed and all the connections have been made.
Accessing the Inside of the System
If rack mounted, grasp the two handles on either side and pull the unit
1.
straight out until it locks (you will hear a "click").
There are two screws that secure the cover to the chassis - remove these
2.
fi rst. Locate the latch on the top (side if tower) of the chassis - depress where
it says "push" then lift the latch to release the cover. You can then lift the
cover from the chassis to gain full access to the inside of the system. See
Figure 2-5.
Checking the Components and Setup
You may have a processor already installed into the serverboard. The proces-
1.
sor should have its own heatsink attached. See Chapter 5 for instructions on
processor installation.
Your system may have come with system memory already installed. Make
2.
sure all DIMMs are fully seated in their slots. For details on adding system
memory, refer to Chapter 5.
If desired, you can install add-on cards to the system. See Chapter 5 for
3.
details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking
4.
the chassis airfl ow. See Chapter 5 for details on cable connections.
Summary of Contents for SuperWorkstation 7046A-6
Page 1: ...SuperWorkstation 7046A 6 SUPER USER S MANUAL 1 0...
Page 5: ...v Preface Notes...
Page 28: ...3 4 SuperWorkstation 7046A 6 User s Manual Notes...
Page 63: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 3 Removing a Chassis Fan...
Page 68: ...6 10 SuperWorkstation 7046A 6 User s Manual Notes...
Page 92: ...7 24 SuperWorkstation 7046A 6 User s Manual Notes...
Page 94: ...A 2 SuperWorkstation 7046A 6 User s Manual Notes...