Chapter 5: Advanced Serverboard Setup
5-7
5-4 I/O
Ports
The I/O ports are color coded in conformance with the PC 99 specifi cation. See
Figure 5-4 below for the colors and locations of the various I/O ports.
Figure 5-4. Rear Panel I/O Ports
5-5 Installing
Memory
Note:
Check the Supermicro web site for recommended memory modules.
CAUTION!
Exercise extreme care when installing or removing DIMM modules
to prevent any possible damage. Also note that the memory is inter-
leaved to improve performance (see step 1).
DIMM Installation (See Figure 5-5)
1. Insert the desired number of DIMMs into the memory slots, starting with DIMM
1A. The memory scheme is interleaved so you must install four modules at a time,
beginning with DIMM 1A, DIMM 2A, DIMM 3A and DIMM 4A and so on. (See the
Memory Installation Table below.) Insert each DIMM module vertically into its slot.
Pay attention to the notch along the bottom of the module to prevent inserting the
DIMM module incorrectly.
2. Gently press down on the DIMM module until it snaps into place in the slot.
Repeat for all modules (see step 1 above).
Summary of Contents for SUPERSERVER 6035B-8R+
Page 1: ... SUPERSERVER 6035B 8R SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 10: ...Notes x SUPERSERVER 6035B 8R User s Manual ...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Rack ...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Page 30: ...SUPERSERVER 6035B 8R User s Manual 3 4 Notes ...
Page 62: ...5 28 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 72: ...6 10 SUPERSERVER 6035B 8R User s Manual Figure 6 6 Replacing a Power Supply Module ...
Page 100: ...A 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 106: ...B 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 110: ...C 4 SUPERSERVER 6035B 8R User s Manual Notes ...