1-4
S
UPER
S
ERVER 6035B-8R+ User's Manual
1-3 Server
Chassis
Features
The following is a general outline of the main features of the SC836S2-R800 server
chassis.
System Power
The SC836S2-R800 features a redundant (two separate power modules) 800W
high-effi ciency power supply with I
2
C. This power redundancy feature allows you
to replace a failed power supply without shutting down the system.
SCSI Subsystem
The SC836S2-R800 chassis was designed to support sixteen dual-channel SCSI
hard drives, which are hot-swappable units.
Note:
The operating system you use must have RAID support to enable the hot-
swap capability of the SCSI drives.
Front Control Panel
The control panel on the SuperServer 6035B-8R+ provides you with system monitor-
ing and control. LEDs indicate system power, HDD activity, network activity, system
overheat and power supply failure. A main power button and a system reset button
are also included. In addition, two USB ports and a COM port have been incorpo-
rated into the front of the chassis for convenient access.
I/O Backplane
The SC836S2-R800 is an ATX form factor chassis designed to be used in a 3U
rackmount confi guration. The I/O backplane provides seven PCI expansion slots,
one COM port, a parallel port, a VGA port, two USB 2.0 ports, PS/2 mouse and
keyboard ports and two gigabit Ethernet ports.
Cooling System
The SC836S2-R800 chassis includes three 8-cm hot-plug system cooling fans
located in the middle section of the chassis. An air shroud channels the airfl ow
from the system fans to effi ciently cool the processors and memory. Two additional
8-cm fans are located at the back of the chassis to expel hot air from the system.
Each power supply modules also include a cooling fan.
Summary of Contents for SUPERSERVER 6035B-8R+
Page 1: ... SUPERSERVER 6035B 8R SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 10: ...Notes x SUPERSERVER 6035B 8R User s Manual ...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Rack ...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Page 30: ...SUPERSERVER 6035B 8R User s Manual 3 4 Notes ...
Page 62: ...5 28 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 72: ...6 10 SUPERSERVER 6035B 8R User s Manual Figure 6 6 Replacing a Power Supply Module ...
Page 100: ...A 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 106: ...B 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 110: ...C 4 SUPERSERVER 6035B 8R User s Manual Notes ...