5-2
S
UPERSERVER 6035B-8R+ User’s Manual
IMPORTANT:
Always connect the power cord last and remove it fi rst before add-
ing, removing or changing any hardware components. Make sure that you install
the processor into the CPU socket
before
you install the heatsink and fan. The
X7DB8+ can support either one or two Xeon LGA 771 processors. If installing
one processor only, install it into CPU socket #1.
Notes:
1. Intel's boxed Xeon CPU package contains a CPU fan and heatsink assembly. If
you buy a CPU separately, make sure that you use only Intel-certifi ed multi-direc-
tional heatsinks and fans.
2. When purchasing an LGA 771 CPU or when receiving a serverboard with an LGA
771 CPU pre-installed, make sure that the CPU plastic cap is in place and none of
the CPU pins are bent; otherwise, contact the retailer immediately.
!
5-2 Processor and Heatsink Installation
When handling the processor, avoid placing direct pressure on the label
area of the fan. Also, do not place the serverboard on a conductive
surface, which can damage the BIOS battery and prevent the system
from booting up.
Installing the LGA 771 Processor
1. A black PnP cap is attached to the
load plate to protect the CPU socket.
Press the load lever down and away
from the retention clasp to release the
load plate from its locked position.
Load lever
2. Gently lift the load lever to open the
load plate.
PnP cap
Load plate released
Summary of Contents for SUPERSERVER 6035B-8R+
Page 1: ... SUPERSERVER 6035B 8R SUPER USER S MANUAL 1 0 ...
Page 5: ...v Preface Notes ...
Page 10: ...Notes x SUPERSERVER 6035B 8R User s Manual ...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Server into a Rack ...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Page 30: ...SUPERSERVER 6035B 8R User s Manual 3 4 Notes ...
Page 62: ...5 28 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 72: ...6 10 SUPERSERVER 6035B 8R User s Manual Figure 6 6 Replacing a Power Supply Module ...
Page 100: ...A 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 106: ...B 6 SUPERSERVER 6035B 8R User s Manual Notes ...
Page 110: ...C 4 SUPERSERVER 6035B 8R User s Manual Notes ...