SC512 Chassis Manual
5-12
System Fan Tray Replacement
Installing the System Fan Tray
Power down the system.
1.
Disconnect each fan from the motherboard.
2.
Lift the system fan tray and fans from the chassis. Retain the rubber mount-
3.
ings that encircle the tray rivets.
Place the fans into the new system fan tray. Make all the fans face the correct
4.
direction.
Confirm the the rubber mountings are in place around the chassis rivets.
5.
Align the fan tray with rivets and place the new fan tray (and system fans)
6.
into the chassis.
Reconnect the system fans to the motherboard
7.
Replacing Individual System Fans
Fans can be replaced individually without removing the system fan tray. There is
no need to power down the system when replacing a system fan.
Replacing System Fans
If necessary, open the chassis while the power is running to determine which
1.
fan has failed. (Never run the server for an extended period of time with the
chassis open.)
Remove the failed fan's power cord from the serverboard.
2.
Lift the failed fan completely from the chassis.
3.
Place the new fan into the vacant space. Make sure the arrows on the top of
4.
the fan (indicating air direction) point in the same direction as the arrows on
the other fan(s).
Confirm that the fan is working properly and replace the chassis cover..
5.
Summary of Contents for SC512C-260 Series
Page 8: ...SC512 Chassis Manual viii Notes...
Page 24: ...SC512 Chassis Manual 3 8 Notes...
Page 28: ...SC512 Chassis Manual 4 4 Notes...
Page 44: ...SC512 Chassis Manual 5 16 Notes...
Page 62: ...SC512 Chassis Manual A 8 Notes...
Page 65: ...B 3 Appendix B SC512F Power Supply Specifications Notes...