2-4
AS1011M-Ni User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the 1011M-Ni into a rack. If the
1011M-Ni has already been mounted into a rack, you can skip ahead to Sections
2-5 and 2-6. There are a variety of rack units on the market, which may mean the
assembly procedure will differ slightly. The following is a guideline for installing
the 1011M-Ni into a rack with the rack rails provided. You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the 1011M-Ni. Each of
these assemblies consist of three sections: an inner fi xed chassis rail that secures
to the 1011M-Ni (A) and an outer fi xed rack rail that secures directly to the rack
itself (B). A sliding rail guide sandwiched between the two should remain attached
to the fi xed rack rail. (See Figure 2-1.) The A and B rails must be detached from
each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out.
Do this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
Mounting Holes
Locking Tab
A
B
Summary of Contents for AS-1011M-Ni
Page 1: ... SUPER AS 1011M Ni USER S MANUAL 1 0a ...
Page 5: ...v Preface Notes ...
Page 10: ...x Notes AS1011M Ni User s Manual ...
Page 16: ...1 6 AS1011M Ni User s Manual Notes ...
Page 26: ...2 10 AS1011M Ni User s Manual Notes ...
Page 30: ...3 4 AS1011M Ni User s Manual Notes ...
Page 86: ...7 18 AS1011M Ni User s Manual Notes ...
Page 88: ...A 2 AS1011M Ni User s Manual Notes ...