NIC: Indicates network activity on either LAN1 or LAN2 when flashing.
Informational LED
Status
Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue (300 mSEC) Remote UID is on. Use this function to identify the
server from a remote location.
•
Information LED
: Alerts operator of several states, as noted in the table below.