52
Super X12DPG-AR User's Manual
Power Button
HDD LED
Ground
Ground
P5V
SCL_SEN
OH/FF LED
19
Ground
20
1
2
Reset/UID
P3V3_STBY
PWR Fail LED
FP PWR LED
3.3V
JFP1
NIC1 (Activity) LED
SDA_SEN
USB Power
UID LED
NIC2 (Activity) LED
FP PWR LED
P5V
1
2
Power Fail LED
The Power Fail LED connection is located on pins 19 of JFP1. When this LED turns solid red,
it indicates a power failure. Refer to the table below for pin definitions.
Information LED (OH/Fan Fail)
LED States
Status
Description
Solid red (on)
An overheat condition has occurred.
Blinking red (1Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25Hz)
Power failure: check for a non-operational power supply
Blinking red (10Hz) (FP red LED)
CPLD recovery mode error(s)
Solid blue
Local UID is activated. Use this function to locate a unit in a rack mount
environment that might be in need of service.
Blinking blue (1Hz)
Remote UID is on. Use this function to identify a unit from a remote location that
might be in need of service.
BIOS/BMC blinking blue (10Hz)
BIOS/BMC: recovery and/or update in progress
Red Info LED blinking (10Hz) and
MB UID LED blue blinking (10Hz)
CPLD: recovery and/or update in progress
Information LED (OH/Fan Fail/PWR Fail)
The Information LED (OH/Fan Fail/PWR Fail/UID LED) connection is located on pins 4 of
JFP1. The LED on pin 4 provides warnings of overheat, power failure, or fan failure. Refer
to the tables below for more information.
1. Power Fail LED
2. Information LED
3. UID LED
UID LED
The unit identifier LED connection is located on pins 3 of JFP1.
3