6-3 System
Fans
Two 10-cm blower fans provide the cooling for the SuperServer 6015V-T/6015V-
TLP. The chassis includes air seals under the blower fans and at the chassis
cross section, which separates the drive bay area from the serverboard area of the
chassis to promote better airfl ow. It is highly important that the air seal is properly
installed and making a good seal in order for the cooling air to circulate properly
through the chassis.
The fans can adjust their speed according to the heat level sensed in the system,
which results in more effi cient and quieter fan operation. Fan speed is controlled
by a setting in BIOS (see Chapter 7).
System Fan Failure
If a fan fails, the ambient air temperature in the chassis will rise and activate the
overheat LED on the control panel. You will need to power down the system to
replace this fan with one of the same type (p/n FAN-0059). Contact your vendor
or Supermicro for information on replacement fans.
Replacing System Cooling Fans
1. Removing a blower fan
After turning off the power to the system, fi rst remove the chassis cover and unplug
the fan cable from the serverboard. Unscrew the failed blower fan from the chassis
and pull it completely out from the serverboard.
2. Installing a new blower fan
Replace the failed fan with an identical 10-cm, 12 volt fan. Position the new fan in
its proper place and secure it to the chassis with the screws you removed previously.
After the new fan has been installed, plug the fan cable back into the same chassis
fan header on the serverboard you removed it from. Make sure the air seal under
the fan is properly installed and creating a good seal. Power up the system and
check that the fan is working properly and that the overheat LED on the control
panel has turned off. Finish by replacing the top panel of the chassis.
Summary of Contents for SUPERSERVER 6015V-T
Page 1: ...SUPER SUPERSERVER 6015V T SUPERSERVER 6015V TLP USER S MANUAL Revision 1 0c ...
Page 5: ...v Preface Notes ...
Page 10: ...Notes SUPERSERVER 6015V T 6015V TLP User s Manual x ...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System ...
Page 30: ...3 4 SUPERSERVER 6015V T 6015V TLP User s Manual Notes ...
Page 66: ...6 8 SUPERSERVER 6015V T 6015V TLP User s Manual Notes ...
Page 98: ...A 6 SUPERSERVER 6015V T 6015V TLP User s Manual Notes ...
Page 104: ...B 6 SUPERSERVER 6015V T 6015V TLP User s Manual Notes ...
Page 118: ...D 4 SUPERSERVER 6015V T 6015V TLP User s Manual Notes ...
Page 122: ...E 4 SUPERSERVER 6015V T 6015V TLP User s Manual Notes ...