7-18
S
UPER
S
ERVER 6015V-M3/6015V-MT User's Manual
Hardware Monitor Logic
Note:
The Phoenix BIOS will automatically detect the type of CPU(s) and hardware
monitoring chip used on the motherboard and will display the Hardware Monitoring
Screen accordingly. Your Hardware Monitoring Screen may look like the one shown
on this page, on page 7-19 or 7-20, depending on the type of CPU(s) and HW
Monitoring chip you are using.
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The hardcode default setting is
80
o
C
. (The default setting for the Intel
5100 Series CPU is
75
o
C
and for the 5000 Series CPU is
80
o
C.)
Temperature Monitoring
(Available if supported by the CPU)
This function monitors the following PECI (Platform Environment Control Interface)
items:
CPU1 Temperature/CPU1 Second Core
CPU2 Temperature/CPU2 Second Core
PECI Agent 1/PECI Agent 2/PECI Agent 3 /PECI Agent 4 Temperature
System Temperature
Fan1-Fan6 Speeds
: If the feature of Auto Fan Control is enabled, the BIOS will
automatically display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vise versa.
If the option is set to “3-pin fan”, the fan speed is controlled by voltage. If the option
is set to “4-pin”, the fan speed will be controlled by Pulse Width Modulation (PWM).
Select “3-pin” if your chassis came with 3-pin fan headers. Select “4-pin” if your
chassis came with 4-pin fan headers. Select “Workstation” if your system is used
as a Workstation. Select “Server” if your system is used as a Server. Select “Dis-
able” to disable the fan speed control function to allow the onboard fans to run at
the full speed (12V) at all the time. The Options are:
1. Disable
, 2. 3-pin (Server),
3. 3-pin (Workstation), 4. 4-pin (Server) and 5. 4-pin (Workstation).
Voltage Monitoring
The following items will be monitored and displayed:
Vcore A:/Vcore B:
-12V/+12V
P1V5
+3.3V
5Vsb
5VDD
P_VTT
Vbat
Summary of Contents for SUPERSERVER 6015V-M3
Page 1: ...SUPER SUPERSERVER 6015V M3 SUPERSERVER 6015V MT USER S MANUAL Revision 1 0b...
Page 5: ...v Preface Notes...
Page 10: ...x Notes SUPERSERVER 6015V M3 6015V MT User s Manual...
Page 30: ...3 4 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 66: ...6 8 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 98: ...A 6 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 104: ...B 6 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 118: ...D 4 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...