The Intel HostRAID Confi gurations
The following types of Intel's HostRAID confi gurations are supported:
RAID 0 (Data Striping): this writes data in parallel, interleaved ("striped") sections
of two hard drives. Data transfer rate is doubled over using a single disk.
RAID1 (Data Mirroring): an identical data image from one drive is copied to another
drive. The second drive must be the same size or larger than the fi rst drive.
RAID 10 (Striping & Mirroring): RAID 0 and 1 schemes are combined (without parity
information) to get the benefi ts of both.
RAID 5: both data and parity information are striped and mirrored across three or
more hard drives.
The Intel Matrix Storage
The Intel Matrix Storage, supported by the ESB2, allows the user to create RAID 0,
1, 10 and 5 sets by using only six identical hard disk drives. The Intel Matrix Storage
Technology creates two partitions on each hard disk drive and generates a virtual
RAID set. It also allows you the change the HDD partition size without any data.
Confi guring BIOS settings for SATA RAID Functions (Native Mode)
1. Press the <Del> key during system bootup to enter the BIOS Setup Utility.
Note: If it is the fi rst time powering on the system, we recommend you load the
Optimized Default Settings. If you have already done so, please skip to Step 3.
2. Use the arrow keys to select the "Exit" Settings. Once in the "Exit" settings,
Scroll down to select "Load Optimized Default Settings" and press the <Enter>
key. Select "OK" to confi rm the selection. Press the <Enter> key to load the default
settings for the BIOS.
3. Use the arrow keys to select the "Main" section in BIOS.
4. Scroll down to "SATA Controller Mode" and press the <Enter> key to select
"Enhanced"
5. Scroll down to "SATA RAID Enabled" and press <Enter>. Then, select "En-
abled."
6. Scroll down to "Exit". Select "Save and Exit" from the "Exit" menu. Press the
<Enter> key to save the changes and exit the BIOS.
7. Once you've exited the BIOS Utility, the system will re-boot.
8. During the system boot-up, press the <Ctrl> and <I> keys simultaneously to run
the Intel RAID Confi guration Utility when prompted by the following message:
Press
<Ctrl> <I> for the
Intel
RAID Confi guration Utility
.
Note: T
he Intel RAID Confi guration Utility is only available for systems with two or
more drives installed. The Intel RAID Utility screen will not display in systems with
one drive installed.
Summary of Contents for SUPERSERVER 6015V-M3
Page 1: ...SUPER SUPERSERVER 6015V M3 SUPERSERVER 6015V MT USER S MANUAL Revision 1 0b...
Page 5: ...v Preface Notes...
Page 10: ...x Notes SUPERSERVER 6015V M3 6015V MT User s Manual...
Page 30: ...3 4 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 66: ...6 8 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 98: ...A 6 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 104: ...B 6 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...
Page 118: ...D 4 SUPERSERVER 6015V M3 6015V MT User s Manual Notes...