background image

www.Superiorfireplaces.US.com

126616-01A

2

Safety .............................................................................................2

Product Dimensions ......................................................................4

Fireplace Installation ......................................................................5

Venting Installation ........................................................................7

Optional Gas Line Installation ......................................................13

Operation and Maintenance Guidelines ........................................14

Replacement Parts .......................................................................15

Technical Service .........................................................................15

Parts ............................................................................................16

Accessories ..................................................................................16

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. 

Pay 

special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.

Register your product online today!

To help us keep you up-to-date on product information and of-

fers, please take a few moments to register your product online 

at www.Superiorfireplaces.US.com 

(Owner Resources/Product 

Registration).

Please read and understand these instructions before installing 

or operating.

SAFETY

 WARNING: Improper installation, adjustment, 

alteration, service or maintenance can cause injury, 

property damage or loss of life. Refer to this manual 

for assistance or additional information. Consult a 

qualified installer or local distributor.

IMPORTANT: Check local codes before installing this 

fireplace.

This fireplace model is a wood burning fireplace intended and ap-

proved for installation in either residential homes or buildings of 

standard construction. This fireplace system requires the utilization 

of INNOVATIVE HEARTH PRODUCTS, LLC’s (IHP) 12", double-wall, 

and snap lock flue pipe system. 
Glass doors are optional with this fireplace and come in different 

styles. For more information see Glass Doors, page 14). Optional 

glass doors in several finishes are available for this fireplace (see 

Replacement Parts, page 15 and Accessories on page 16).
Before beginning installation of this fireplace, read these instructions 

through completely.

•  This  IHP  fireplace  and  its  components  are  safe  when  installed 

according to this installation manual. Unless you use IHP com-

ponents, which have been designed and tested for the fireplace 

system, you may cause a fire hazard.

•  The IHP warranty will be voided by and IHP disclaims any respon

-

sibility for the following actions.

a. Modification of the fireplace or any of the components manu-

factured by IHP unless otherwise permitted by IHP.
b. Use of any component part not manufactured or approved by 

IHP in combination with an IHP fireplace system.
c. Installation and/or operation in a manner other than instructed 

in this manual.
d. The burning of any other fuel not tested or approved by IHP  

in this wood burning fireplace.

Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Consult the local building codes 

as to the particular requirements concerned with the installation of 

TABLE OF CONTENTS

all factory built fireplaces.
Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Although grounding may not 

be required by code in your area, it must be electrically grounded in 

accordance with local codes or, in the absence of local codes, with 

the National Electrical Code, ANSI/NFPA 70-1990.
This fireplace is intended for installation in accordance with the 

National Fire Protection Association Standard for Chimneys, Fire-

places, Vents and Solid-Fuel Burning Fireplaces, NFPA 211, and in 

accordance with codes such as the BOCA Basic/National Code, the 

Standard Mechanical Code, and the Uniform Building Code.

 WARNING: Do not install a fireplace insert in this 

fireplace unless the manufacturer's instructions with 

the insert specifically state this fireplace has been 

tested for use with this insert.

FOR YOUR SAFETY

• Do not store or use gasoline or any other flammable 

vapors or liquids in the vicinity of this or any other 

appliance.

• Due to high temperatures, the appliance should be 

located out of traffic and away from furniture and 

draperies.

• Do not place clothing or other flammable materials 

on or near the appliance.

• Never  leave  children  unattended  when  a  fire  is 

burning in the fireplace.

 WARNING: Use solid wood or processed solid 

fuel fire logs only. "Do not poke or stir the logs while 

they are burning. Use only firelogs that have been 

evaluated for the application in fireplace and refer to 

firelog warnings and caution markings on packaging 

prior to use."

Summary of Contents for Custom WRT40PFWS

Page 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Page 2: ...re hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherw...

Page 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Page 4: ...up has occurred When creosote has accumulated 1 8 3mm ormore itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or...

Page 5: ...locate in or near an area where gasoline or other flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this firep...

Page 6: ...of fireplace see Figure 8 Figure 6 Framing Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in fr...

Page 7: ...t For operating instructions please refer to your owner s manual FIREPLACE INSTALLATION Continued 8 Max K Factor 84 1 1 2 Typ 1 1 2 Typ Noncombustible Hearth Extension Z Type Ember Protector Noncombus...

Page 8: ...engths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected...

Page 9: ...and Accessories page 16 VENTING INSTALLATION Continued 10 FOOT RULE All chimney terminations must extend a minimum of 3 feet above the highest point where it passes through the roof and must be at le...

Page 10: ...n usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing re...

Page 11: ...th the termination being used Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Figure 24 Flashing Installation Flashing Cone Overlap Shingles Top and Sides Only Figure 25...

Page 12: ...ombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles p...

Page 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Page 14: ...oors and never allow flames to contact the glass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT...

Page 15: ...h surface temperatures and to stay away from these to avoid burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENA...

Page 16: ...R FS 10 for Straight Pipe 30FS 10 for 30 Angled Run DOUBLE WALL 30 ELBOW OFFSET 30E 12DM Also available in triple wall Return Elbow Starter Elbow DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12...

Page 17: ...DM 6 12 TO 12 12 PITCH V12F 10DM ECONO TOP TERMINATION STL 12DM BI FOLD GLASS DOOR DG36PN Brushed Brass DC36PN Platinum DBPPN36 Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 R...

Page 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126616 01 Rev A 01 20...

Reviews: