background image

www.Superiorfireplaces.US.com

126616-01A

13

 WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

A gas line may be installed for the purpose of installing a vented 

or vent-free decorative gas appliance available through your local 

distributor. Use only gas piping approved by local codes. When 

installing a gas line, a shutoff valve designed for installation outside 

the appliance is recommended.
The gas pipe is intended for connection to a decorative gas ap-

pliance that operates using natural or propane/LP gas only. This 

appliance must have an automatic shutoff device and must comply 

with the Standard for Decorative Gas Appliances for Installation in 

Vented Fireplace, ANSI Z21.60. ONLY UNVENTED GAS LOG SETS 

WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR 

UNVENTED ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED 

IN THIS FIREPLACE.

NOTICE:

 Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.
1.  Remove knockout indentation on refractory or firebrick wall 

located approximately 2" above the refractory hearth floor. The 

knockout indentation must be firmly tapped with any solid object 

such as a 1/2" dowel until it is released. Remove fragmented 

portions of refractory (see Figure 29).

2.  Remove gas line cover plate located on rear of fireplace and pull 

out insulation from gas line conduit sleeve. Save insulation for 

reuse.

3.  Run 1/2" black iron gas line into the firebox through the rear at 

11 1/4" from floor and through gas line conduit sleeve (if using 

a raised platform, add height). Provide sufficient gas line into 

firebox chamber for fitting connection (see Figure 30).

 

Note: 

Secure incoming gas line to wood framing to provide rigidity 

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal 

any gaps between gas line and refractory knockout hole with 

refractory cement or commercial furnace cement, Install the gas 

appliance or cap off gas line if desired.

 CAUTION: All gas piping and connections must be 

tested for leaks after installation is completed. After 

ensuring that gas valve is on, apply soap and water 

solution to all connections and joints. Bubbles forming 

show a leak. Correct all leaks at once. DO NOT USE 

AN OPEN FLAME FOR LEAK TESTING AND DO NOT 

OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 

LEAK TESTING SHOULD BE DONE BY A QUALIFIED 

SERVICE PERSON.

Note: 

An IHP hood must be installed when using an unvented gas 

log set (see Accessories on page 16).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with chimney removed.

Figure 30 - Gas Line Installation

OPTIONAL GAS LINE INSTALLATION

Figure 29 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End for 

Fitting Connection

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

Summary of Contents for Custom WRT40PFWS

Page 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Page 2: ...re hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherw...

Page 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Page 4: ...up has occurred When creosote has accumulated 1 8 3mm ormore itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or...

Page 5: ...locate in or near an area where gasoline or other flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this firep...

Page 6: ...of fireplace see Figure 8 Figure 6 Framing Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in fr...

Page 7: ...t For operating instructions please refer to your owner s manual FIREPLACE INSTALLATION Continued 8 Max K Factor 84 1 1 2 Typ 1 1 2 Typ Noncombustible Hearth Extension Z Type Ember Protector Noncombus...

Page 8: ...engths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected...

Page 9: ...and Accessories page 16 VENTING INSTALLATION Continued 10 FOOT RULE All chimney terminations must extend a minimum of 3 feet above the highest point where it passes through the roof and must be at le...

Page 10: ...n usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing re...

Page 11: ...th the termination being used Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Figure 24 Flashing Installation Flashing Cone Overlap Shingles Top and Sides Only Figure 25...

Page 12: ...ombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles p...

Page 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Page 14: ...oors and never allow flames to contact the glass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT...

Page 15: ...h surface temperatures and to stay away from these to avoid burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENA...

Page 16: ...R FS 10 for Straight Pipe 30FS 10 for 30 Angled Run DOUBLE WALL 30 ELBOW OFFSET 30E 12DM Also available in triple wall Return Elbow Starter Elbow DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12...

Page 17: ...DM 6 12 TO 12 12 PITCH V12F 10DM ECONO TOP TERMINATION STL 12DM BI FOLD GLASS DOOR DG36PN Brushed Brass DC36PN Platinum DBPPN36 Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 R...

Page 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126616 01 Rev A 01 20...

Reviews: