VENTING INSTALLATION 

Continued

PIPE INSTALLATION

The pipe sections must be assembled independently as the chimney 

is installed. When connecting chimney directly to the fireplace, the 

inner flue pipe section must be installed first with the lanced side up. 

The outer pipe section can then be installed over the flue pipe section 

with the hemmed end up. Press down on each pipe section until the 

lances securely engage the hem on the fireplace starter. The wire will 

assure the proper spacing between the inner and outer pipe sections.
Continue to assemble chimney sections as outlined above, making 

sure that both the inner and outer pipe sections are locked together. 

When installing double wall snap-lock chimney together, it is impor-

tant to assure the joint between the chimney sections is locked. Check 

by pulling chimney upward after locking. The chimney will not come 

apart if properly locked. It is not necessary to add screws to keep the 

chimney together (exception, see Figure 17, page 9).

 WARNING: The opening in collar around chimney 

at top of fireplace must not be obstructed. Never use 

blown insulation to fill chimney enclosure.

CHIMNEY PIPE

The IHP chimney system is a snap-lock, double-wall pipe. It consists 

of a stainless steel inner flue pipe(s), a galvanized outer pipe and a 

wire spacer. Each section of pipe comes in lengths of 12", 18", 36" 

and 48". The actual lineal gain for each is measured after each section 

is fully connected. Lineal gain is the actual measurable length of a 

part after two or more parts are connected.

USING ELBOW OFFSETS AND SUPPORTS

Chimney weight above offset rests on return elbow. Straps must be 

securely nailed to rafters or joists (see Figure 15). 
To achieve desired offset, you may install combinations of 12", 18", 

36" and 48" length of double wall pipe (see offset chart and Figure 16).
Maximum length of pipe between supports is 6 feet of angled run. A 

maximum of two 6 feet angled run sections per chimney system (see 

Figure 18).

SUPPORT SECTIONS

The chimney support section is a 4" strap and 12" length of pipe. 

A chimney support is required every 30 feet above fireplace after a 

straight chimney run or above a return elbow after a straight chimney 

run (see Figure 17, page 9). This support is designed to relieve the extra 

weight load on fireplace and elbows when high chimneys are installed.

Figure 15 - Elbow Offset

30 FT.

(9.14m)

30 FT.

(9.14m)

Return 

Elbow

12S-12DM

Support 

Required

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

WRT40PFWS

Peninsula Fireplace

52 

3

/

4

"

48-12DM

48-12TM

Flue Pipe

46 

5

/

8

"

36-12DM

48-12TM

Flue Pipe

34 

5

/

8

"

24-12DM

48-12TM

Flue Pipe

22 

5

/

8

"

18-12DM

48-12TM

Flue Pipe

16 

5

/

8

"

12-12DM

48-12TM

Flue Pipe

10 

5

/

8

"

STL-12D

Chase Style 

Termination

1" to 12"

RLT-12D

Round Top 

Termination

7"

OFFSET CHART

OFFSET RISE

CHIMNEY LENGTH

A

B

48" 36" 18" 12"

3

/

8

"

16 

3

/

8

"

ELBOW SET ONLY

1

/

2

"

25 

1

/

4

"

1

12 

1

/

2

"

30 

3

/

8

"

1

14 

3

/

8

"

34"

2

17 

5

/

8

"

39 

1

/

4

"

1

1

21 

1

/

2

"

46"

1

22 

3

/

4

"

48 

1

/

8

"

1

2

26 

3

/

8

"

54 

7

/

8

"

1

26 

3

/

8

"

60"

1

1

31 

3

/

4

"

63 

3

/

4

"

1

1

34 

3

/

4

"

69"

1

1

38 

5

/

8

"

75 

5

/

8

"

2

39 

7

/

8

"

77 

7

/

8

"

1

1

1

43 

3

/

4

"

84 

1

/

2

"

1

1

46 

3

/

4

"

87 

3

/

4

"

2

1

48 

7

/

8

"

93 

3

/

8

"

2

Summary of Contents for Custom WRT40PFWS

Page 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Page 2: ...re hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherw...

Page 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Page 4: ...up has occurred When creosote has accumulated 1 8 3mm ormore itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or...

Page 5: ...locate in or near an area where gasoline or other flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this firep...

Page 6: ...of fireplace see Figure 8 Figure 6 Framing Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in fr...

Page 7: ...t For operating instructions please refer to your owner s manual FIREPLACE INSTALLATION Continued 8 Max K Factor 84 1 1 2 Typ 1 1 2 Typ Noncombustible Hearth Extension Z Type Ember Protector Noncombus...

Page 8: ...engths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected...

Page 9: ...and Accessories page 16 VENTING INSTALLATION Continued 10 FOOT RULE All chimney terminations must extend a minimum of 3 feet above the highest point where it passes through the roof and must be at le...

Page 10: ...n usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing re...

Page 11: ...th the termination being used Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Figure 24 Flashing Installation Flashing Cone Overlap Shingles Top and Sides Only Figure 25...

Page 12: ...ombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles p...

Page 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Page 14: ...oors and never allow flames to contact the glass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT...

Page 15: ...h surface temperatures and to stay away from these to avoid burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENA...

Page 16: ...R FS 10 for Straight Pipe 30FS 10 for 30 Angled Run DOUBLE WALL 30 ELBOW OFFSET 30E 12DM Also available in triple wall Return Elbow Starter Elbow DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12...

Page 17: ...DM 6 12 TO 12 12 PITCH V12F 10DM ECONO TOP TERMINATION STL 12DM BI FOLD GLASS DOOR DG36PN Brushed Brass DC36PN Platinum DBPPN36 Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 R...

Page 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126616 01 Rev A 01 20...

Reviews: