VENTING INSTALLATION 

Continued

MINIMUM/MAXIMUM CHIMNEY HEIGHT

The minimum height of the chimney (measured from the base of the 

fireplace to the flue gas outlet-end of pipe) is 16 feet for a straight run, 

16 feet minimum for a run with 1 elbow set and 25 feet minimum for 

a run with 2 elbow sets. (A set consists of one starter elbow and one 

return elbow.)
Uncommon circumstances such as neighboring hills, tall trees, or 

strong wind areas can cause down drafts in chimney system. In such 

cases, going beyond the minimum recommended height would be 

preferable to provide a better draw.
The fireplace height approved for any chimney run with this fireplace 

system is 40 feet measured from bottom of firebox to flue outlet-end 

of pipe (see Figure 22).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with the chimney removed.

PENETRATING ROOF

To maintain a 2" clearance to pipe on a roof with a pitch, a rectangular 

opening must be cut.
1.  Determine center point where pipe will penetrate the roof.
2.  Determine center point of the roof. Pitch is the distance the roof 

drops over a given span, usually 12". A 6/12 pitch means that the 

roof drops 6" for each 12" one measure horizontally down from 

roof rafters.

3.  Use roof opening chart (Figure 23) to determine correct opening 

length and flashing required.

4.  Remove shingles around opening measured. Cut out this section.
5.  Add next sections of pipe until end penetrates roof line. Check to see 

that proper clearances are maintained. Extend chimney by adding 

sections of double wall pipe until pipe is minimum of 30" above 

highest point of roof cutout. Termination and chimney must extend 

a minimum of 36" above highest point where it passes through the 

roof (see 10-Foot Rule and Figure 21, page 9.

Figure 22 - Maximum Chimney Height

Figure 23 - Roof Opening Measurements

FLASHING INSTALLATION

Determine flashing to be used with roof opening chart. Slide flashing 

over pipe until base is flat against roof. Replace as many shingles as 

needed to cover exposed area and flashing base. Secure in position 

by nailing through shingles (see Figure 24). 

DO NOT NAIL THROUGH 

FLASHING CONE

.

Pitch

Slope Opening "A" 

Max. 

Used Flashing

Model No. 

Flat

19"

V6F-10DM

0-6/12 26.6°

23.25"

V6F-10DM

6/12-

12/12

45°

30.75"

V12F-10DM

Opening

“A”

19" Min.

(48.26cm)

30" Min.

(76.2cm)

2" Min.

(5.08cm)

2" Min.

(5.08cm)

2" Min.

(5.08cm)

Maximum

Height

Chase

Termination

50 Ft.

Minimum

Height

15 Ft.

Storm 

Collar

Flashing

Firestop 

Spacer

RLT-12D

RLT-12D STL-12D

Summary of Contents for Custom WRT40PFWS

Page 1: ...e is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard...

Page 2: ...re hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace or any of the components manu factured by IHP unless otherw...

Page 3: ...urn veryquickly DONOTusetreatedwood charcoal coal trash driftwoodorwoodsthathavebeendippedintar pitch pine tar creosote etc Wood products made with synthetic binders such as plywood produce ab normall...

Page 4: ...up has occurred When creosote has accumulated 1 8 3mm ormore itshallberemoved to reduce the risk of a chimney fire SAFETY Continued Figure 1 Dimensions WARNING Always leave glass doors fully opened or...

Page 5: ...locate in or near an area where gasoline or other flam mable liquids may be stored The firebox area must be kept clear and free from these combustible materials The typical installation for this firep...

Page 6: ...of fireplace see Figure 8 Figure 6 Framing Firebox with Z Type Ember Protectors Figure 7 Ember Protectors Figure 8 Nailing Flanges HEARTH EXTENSIONS A hearth extension projecting a minimum of 20 in fr...

Page 7: ...t For operating instructions please refer to your owner s manual FIREPLACE INSTALLATION Continued 8 Max K Factor 84 1 1 2 Typ 1 1 2 Typ Noncombustible Hearth Extension Z Type Ember Protector Noncombus...

Page 8: ...engths of 12 18 36 and 48 The actual lineal gain for each is measured after each section is fully connected Lineal gain is the actual measurable length of a part after two or more parts are connected...

Page 9: ...and Accessories page 16 VENTING INSTALLATION Continued 10 FOOT RULE All chimney terminations must extend a minimum of 3 feet above the highest point where it passes through the roof and must be at le...

Page 10: ...n usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from roof rafters 3 Use roof opening chart Figure 23 to determine correct opening length and flashing re...

Page 11: ...th the termination being used Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Figure 24 Flashing Installation Flashing Cone Overlap Shingles Top and Sides Only Figure 25...

Page 12: ...ombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and fireplace openings are not obstructed in any way see Minimum Clearance to Combustibles p...

Page 13: ...tween gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be...

Page 14: ...oors and never allow flames to contact the glass WARNING FIREPLACESEQUIPPEDWITHDOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPENORDOORSFULLYCLOSED IFDOORSARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT...

Page 15: ...h surface temperatures and to stay away from these to avoid burns or clothing igni tion Young children should be carefully supervised when they are in the same room as fireplace OPERATION AND MAINTENA...

Page 16: ...R FS 10 for Straight Pipe 30FS 10 for 30 Angled Run DOUBLE WALL 30 ELBOW OFFSET 30E 12DM Also available in triple wall Return Elbow Starter Elbow DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12...

Page 17: ...DM 6 12 TO 12 12 PITCH V12F 10DM ECONO TOP TERMINATION STL 12DM BI FOLD GLASS DOOR DG36PN Brushed Brass DC36PN Platinum DBPPN36 Black ACCESSORIES Continued OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4 R...

Page 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126616 01 Rev A 01 20...

Reviews: