background image

Superiorfireplaces.US.com

126746-01D

12

Figure 12 - Removing Front Refractory Access Panel 

(BRT2532TEN Model Shown)

GAS LINE HOOK-UP

 WARNING: Gas line hookup should be done by your 

gas supplier or a qualified service person.

 WARNING: Before you proceed, make sure your 

gas supply is OFF.

The appliance and it’s individual shutoff valve must be disconnected 

from the gas supply piping system during any pressure testing of 

gas supply piping system at test pressures in excess of 1/2 psi (3.5 

kPa). Appliance must be isolated from gas supply piping system 

by closing its individual manual shutoff valve during any pressure 

testing of gas supply piping system at test pressures equal to or less 

than 1/2 psi (3.5 kPa).
A manual shutoff valve has been included in the appliance’s gas sup-

ply system. You may consider installing an extra gas shutoff valve 

outside the appliance’s enclosure (check with local codes) where 

it can be accessed more conveniently with a key through a wall as 

shown in Figure 14, page 13.
In conformance with local codes, route a 1/2" NPT gas line towards 

appliance coming in from any of the 3 directions shown in Figure 15.

 CAUTION: Do not kink flexible gas line.

FIREPLACE INSTALLATION 

Figure 13 - Installing the WRC Remote Receiver

Figure 13A - Installing Battery into Back of Handset

Fireplace 

Receptacle

Remote 

Control 

Receiver

Extension 

Cord

Ignition Module 

Plug

Pull to Remove 

Insulation Tab

Battery Cover

12 Volt Battery

Back of 

Handset

WALL SWITCH INSTALLATION

The installation of a wall switch allows you to activate the gas control 

valve and turn the fireplace on and off. The wall switch is to be con-

nected to the incoming 120 volt regular household wiring that sup-

plies the electricity to the fireplace. Refer to Wiring Diagram, page 29.

OPTIONAL REMOTE CONTROL INSTALLATION (MODEL WRC)

Note: If using optional wireless hand-held remote control, wall switch 

must be in ON position to be operational. The remote control then 

becomes the switching mechanism for fireplace operation.
1.  Remove front refractory access panel by lifting up and angling 

out of firebox opening (see Figure 12).

2.  WRC model receiver does not require a battery. Receiver can 

be installed by first plugging short extension cord into fireplace 

receptacle. Plug receiver unit into extension cord. Finally, plug 

ignition module plug into receiver unit (see Figure 13).

3.  Activate remote handset battery by removing insulating tab 

on back of handset (see Figure 13A). Battery is included pre-

installed.

4.  Once battery is activated, unit is ready to use.
5.  Replace front refractory access panel

Summary of Contents for BRT2032TEN

Page 1: ...ncindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W...

Page 2: ...lation and operational procedures For assis tance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanent...

Page 3: ...he fireplace in high traffic areas in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Fireplace wi...

Page 4: ...an the type of gas approved for use in this gas appliance Installation must conform with local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 This fireplace...

Page 5: ...PROPANE LP Max Input Rating 15 000 Btu Hr 25 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13...

Page 6: ...d or at a premium and since the space required to enclose the appliance would be located beyond an outside wall this would also reduce the cutting of joists roof rafters and such Check local codes for...

Page 7: ...ling 0 Clearance Ceiling 1 2 5 cm Min Clearance to B Vent s Outer Pipe Required Air Spaces are Indicated with an Do Not Pack with Insulation or Any Other Material DO NOT BLOCK OR OBSTRUCT OPENINGS 0 C...

Page 8: ...itting at the end of flexible gas line remove fitting and replace with a 37 degree flare 3 4 12 1 2 NPT female fitting WARNING When finishing appliance do not overlap combustible material onto the bla...

Page 9: ...t above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT...

Page 10: ...lateral length must exceed 75 then the system must be sized in accordance with the Category I venting tables Example 2 shows a multiple offset each at 45 of inclination Multiple offsets are permitted...

Page 11: ...8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Ove...

Page 12: ...TALLATION Figure 13 Installing the WRC Remote Receiver Figure 13A Installing Battery into Back of Handset Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Pull to Remov...

Page 13: ...leaks after the installation is completed After ensuring that the gas valve is on apply a non corrosive leak detection solution to all connections and joints If bubbles appear leaks can be detected an...

Page 14: ...1 2 gap under the lower grate members to allow air to flow see Figure 21 LOG PLACEMENT FOR BRT2032TEN MODEL 1 Place front log onto front of grate sliding log all the way forward against grate fingers...

Page 15: ...ace top of log 4 into notch on log 1 Rest log 4 on the center of grate as shown in Figure 26 5 Place top of log 5 into notch on top right of log 1 see Figure 26 Rest log 5 between two middle grate fin...

Page 16: ...ge of firebox opening 4 Tilt door assembly fully vertical until outer pivot pin snaps into mounting hole in upper spring clip see Figure 30 5 Once top and bottom pins are secured unfold door into clos...

Page 17: ...ly Opened Door Figure 32 Removing Glass Doors Spring Clip Press Spring Clip to Release Pivot Pin Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track Pivot Plate Fold Bi Fold D...

Page 18: ...TRUCTIONS NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be present Open damper or window to vent smell This will only last a...

Page 19: ...s panel 7 Fully close glass doors if installed Figure 34 Pilot OPTIONAL HAND HELD REMOTE OPERATION Note The WRC receiver and hand held remote control kit must be purchased separately see Accessories p...

Page 20: ...ng page 21 Figure 36 Typical Flame Pattern BRT2332TEN BRT2532TEN Models BRT2032TEN Model WARNING Installation and repair should be done by a qualified service person The appliance should be inspected...

Page 21: ...service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Replace...

Page 22: ...let blocked 3 Burner flame holes blocked 4 Improper venting or excessive blockage 5 Excessive amounts of embers and pan mate rial OBSERVED PROBLEM Nogastoburner althoughwallswitchandvalve are set to t...

Page 23: ...n calling please have your model and serial numbers of your fireplace ready You can also visit our web site at IHP US com ACCESSORIES Purchase these accessories from your local dealer If they can not...

Page 24: ...032TEN 33 43 41 15 19 24 14 30 26 29 3 14 12 13 23 35 16 31 32 32 38 39 40 40 4 34 21 20 22 5 5 37 42 1 1 36 28 25 9 2 7 17 11 6 27 10 11 24 3 18 18 24 9 NG LP 24 8 24 8 24 4 24 9 24 12 24 10 24 11 24...

Page 25: ...03 Burner Pan 1 24 2 109794 01 Burner Tube 1 24 3 107748 01 Burner Bracket 1 24 4 107985 01 Pilot Shield 1 24 5 109793 01 Divider Pan 1 24 6 11209 Nut 10 24 1 24 7 11147 Screw 10 24x1 2 1 24 8 901066...

Page 26: ...3 43 41 15 19 24 14 30 26 29 17 14 12 13 24 3 18 18 24 9 NG LP 24 8 24 8 24 4 24 9 24 12 24 10 24 11 24 6 24 2 24 5 24 1 24 7 23 10 36 9 36 35 16 31 32 32 38 39 40 40 4 34 21 8 46 45 44 44 11 37 42 1...

Page 27: ...12 06 Burner Assembly 1 24 1 107742 03 Burner Pan 1 24 2 109037 01 Burner Tube 1 24 3 107748 01 Burner Bracket 1 24 4 107985 01 Pilot Shield 1 24 5 901681 01 Burner Clamp 1 24 6 11209 Nut 10 24 1 24 7...

Page 28: ...al KEY NO PART NO DESCRIPTION QTY 109109 01 Log Set 1 105958 05 Front Log 1 2 105960 05 Rear Log 1 3 901100 02 Top Right Log 1 4 901102 02 Top Left Log 1 1 4 2 3 1 2 3 4 5 KEY NO PART NO DESCRIPTION Q...

Page 29: ...TOFF SWITCH EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC 120V AC 120V AC INCOMING OR BREAKER FUSE BOX OFF ON SUPPLIED WALL SWITCH GREEN BLACK WHITE 120v 60Hz 0 7A ELECTRICAL RATING BLACK...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in...

Page 32: ...mation Printed in U S A 2013 IHP LLC P N 126746 01 Rev D 10 2014 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 IHP US com KEEP THIS WARRANTY Model located on product or identification...