Superiorfireplaces.US.com
126746-01D
20
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame. Alterations
may have occurred during shipping and handling. The pilot is located
on the back right hand side of burner.
The flame must envelope 1/4" of top of the ignitor/sensor and
grounding stem.
If your pilot assembly does not meet these requirements:
•
Turn adjustment screw marked PILOT clockwise to decrease or
counterclockwise to increase flame to proper size (see Figure
35). Do not remove adjustment screw.
•
see Troubleshooting, page 21
INSPECTING BURNERS
CLEANING AND MAINTENANCE
Figure 35 - Correct Pilot Flame Pattern
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. Flames should
go up through the middle of log set. Flames should not "spill" to the
edges of the pan or sides of the log set.
Figure 36 shows a typical flame pattern. If burner flame pattern dif-
fers from that described:
• turn appliance off (see
To Turn Off Gas to Appliance, page 19)
• see
Troubleshooting, page 21
Figure 36 - Typical Flame Pattern
(BRT2332TEN/BRT2532TEN) Models
(BRT2032TEN) Model
WARNING: Installation and repair should be done
by a qualified service person. The appliance should
be inspected before each use and at least annually
by a qualified service person. More frequent cleaning
may be required due to excessive lint from carpeting,
bedding material, pet hair, etc. It is imperative that
the control compartments, burners, and circulating
air system be kept clean.
WARNING: Logs can be hot. Handle only when
cool.
WARNING: Turn off gas and electrical power before
servicing appliance.
PILOT AND BURNER
• Remove logs and ember material before cleaning burner and
replace when cleaning is complete.
• Burner and controls should be cleaned with compressed air to
remove dust, dirt, or lint.
• Use a vacuum cleaner or small, soft bristled brush to remove
excess dust, dirt, or lint.
LOGS
• If you remove logs for cleaning, refer to log placement information
on page 14 to properly replace logs.
• Use a vacuum cleaner to remove any carbon buildup on logs.
• Replace log(s) if broken. See
Replacement Parts, page 23.
• Replace ember material periodically as needed. See
Replacement
Parts, page 23.
Pilot
Burner
Ignitor/
Sensor
Sensing
Rod