Premier VS Infrared Heating System
Page 13
June 04, 2014
EQUIPMENT SPECIFICATIONS
*For more Gas Connection details refer to Part 4 -
Gas Supply System on page 51.
VL017
02/10
Premier
VS - Chart of Burner Rates
End Vent
Vacuum
(in. wc)
Burner Position 1
Flow Plate No. 1
Rate (BTUH)
Burner Position 2
Flow Plate No. 2
Rate (BTUH)
Burner Position 3
Flow Plate No. 3
Rate (BTUH)
4.5
3.6
3.0
2.0
1.7
250,000
225,000
200,000
175,000
150,000
165,000
130,000
120,000
130,000
120,000
Superior Radiant Products Ltd.
Stoney Creek, ON
Important:
This burner is a variable input appliance.
See chart below to determine appliance burn rate.
Natural Gas requires a No.
S
drill size orifice.
LP Gas requires No.
K
drill size orifice.
A conversion kit as supplied by the manufacturer shall be used to
covert to the alternate fuel.
A flow plate appropriate to the position of the burner in the system
MUST be installed (see Manufacturer's Instructions).
Positions are identified in ascending order from the start end of the system.
Note:
An end vent vacuum intermediate to those shown will result
in rates intermediate and proportional to those indicated.
VS Burner Rates – VL017
Gas Connection Label - CL034
(on a YELLOW Background)
90°
12"
45°
45°
WARNING
: Connector Must Be Installed As Shown Above.
CL034
Heater Movement
End View
3" Max.
Displacement
For US
use only
1
2
" x 24" or 36" SS ; or
3
4
" x 24" SS for burners over 150 MBTU
For Canada
use only
1
2
" x 30" rubber ; or
3
4
" x 30" rubber for burners over
150 MBTU. Gas connector sold separate from heater.