NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21
9
10
Wiring - Fireplace (See
Figures 27 and 28 on Page 22)
NOTE: These electronic appliances must be connected to the main
power supply. The gas valve is set in place and pre-wired at the factory.
1
. Route a 3-wire 120 Vac 60 Hz 1ph power supply to the appliance
junction box.
2
. Remove the electrical inlet cover plate from the side of the unit by remov-
ing the plate securing screws (see
Figure 8 on Page 12
)
.
3
. Remove the cover plate knockout and then feed the power supply through
the knockout opening and into the unit junction box.
4
. Connect the black power supply to the
power outlet
red pigtail lead and
the white power supply to the
common
terminal of the outlet as shown in
Figures 27 and 28 on Page 22.
5
.
Connect the ground supply to the pigtail lead attached to outlet
green ground screw.
6
. Wall-mounted ON/REMOTE/OFF burner control switch and remote
control kits may be used. Mount the switch in a convenient location
on a wall near the fireplace.
NOTE: One end of the supplied wire (15 ft) is factory-connected and
the other end is attached to the side of the unit.
CAUTION: Do Not connect the ON/REMOTE/OFF wall switch to a 120
V power supply.
8
. Turn the wall-mounted ON/REMOTE/OFF burner control switch to the
OFF position.
9
. After the wiring is complete, replace the cover plate.
Wiring - Power Vent Termination
Alternate Instructions
(For use when access to the termination is easy
and a secondary electrical junction box installation is not desired).
• Remove the junction box cover from the termination by removing the
attaching screw (see
Figure 23
)
.
• Loosen the strain relief on the termination shown in
Figure 25
. Pull
the pigtail in and shorten it to fit within the junction box cover.
WARNING: Crimp connectors may be used on stranded cables (such as
SJOT cable) only. Solid wire Romex must be connected per the National
Electric Code, NEC 70 - latest version, or local codes.
• Route 14 gage AWG grounded solid wire Romex or equally sized
stranded cable (e.g., SJOT) from the fireplace to the newly installed
junction box near the termination. Ensure the cable is safety plated to
prevent damage from framing nails and finish drywall screws. Route
it into the lower control compartment and cut to length before install-
ing the terminals. Install provided hardware on the ends of the cable.
Cable is not provided. The provided crimp terminals are intended for
use with stranded cable. If using Romex, connect per National Electric
Code or local code.
Attaching Screw
Pigtail
Junction Box Cover
Cable
Black and White
Ground Wire
Strain Relief
Ground Cable to
The Termination
Pigtail Wires Cut
Off and Shortened
Wire Nuts
Strain Relief Holding Cable
• Refer to
Figure 26
and install the electrical hardware on the fireplace
end of the cable. Male terminals (#10) on the Black and White wires,
and ring terminals (#9) on the ground. The termination end of the cable
will be connected to the termination with wire nuts (not provided).
• Refer to
Figure 26
to connect the three wires of the cable to the termina-
tion. Ensure the ground ring terminal is grounded beneath a structural
screw as shown. Attach the junction box cover to the termination with
the screw previously removed.
• The fireplace end of the cable will be addressed in
Connecting The
Power Vent To The Fireplace Control System
.
Cable
Figure 23 - Bottom of Termination
Figure 24 - Cable Connections
Figure 25 - Back of Termination
Figure 26 - Junction Box Cover Removed
INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340TYN AND DRT6345TYN) • INSTALLATION INSTRUCTIONS
f i r e - p a r t s . c o m