background image

55

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. C  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The product body, firebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 

against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 

Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 

replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 

pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The product body, firebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded 

from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

10

/14

/20

15

f i r e - p a r t s . c o m

Summary of Contents for DRT6300 Series

Page 1: ...r de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoiventêtreassuréspar un installateur ou un service d entretien qualifié ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Installateur Laissez cette ...

Page 2: ...RE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Vea el volante adjunto para la representación de color adecuado See attached...

Page 3: ...duras graves si se toca Mantenga a los niños alejados de la chimenea en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadame...

Page 4: ...ustments Page 43 Electronic Appliance Inspection Page 44 Ordering Replacement Parts Page 45 Accessory Components Page 46 Lighting Instructions Page 48 Maintenance Schedule Page 50 Troubleshooting Page 51 Replacement Parts List Page 53 Warranty Page 55 Pleasereadandunderstandtheseinstruc tions before beginning your installation NOTE IF THE BARRIER BECOMES DAMAGED THE BARRIER SHALL BE REPLACED WITH ...

Page 5: ...parts in accordance with these diagrams orfailuretouseonlypartsspecifi callyapprovedwiththisappliance may result in property damage or personal injury AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvéesaveccetappareilsont utilisées WARNING Clothing or other flammable materia...

Page 6: ...o operate for approximately fifteen 15 seconds after shutdown to expel the exhaust gases from the venting system These appliances are listed by Intertek for installation in bedrooms and manufactured mobile homes Installation must conform to local codes In the absenceoflocalcodes installationmustcomply with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in Canada the current CAN CGA B149 1 ...

Page 7: ...ctural integrity of the manufactured home floor wall and ceiling roof must be maintained CAUTION This appliance must be grounded to the chassis of the manu factured home in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition COMMONWEALTHOFMASSACHUSETTS REQUIREMENTS Theseappliancesareapprovedforinstallationin the US state of Mas...

Page 8: ...Objects placed above the unit are exposed to elevated temperatures Do not insulate the space between the appli ance and the area above it The appliance must be mounted on a fully supported base extending the full width and depth of the unit The appliance may be lo cated on or near conventional construction materials However if installed on combustible materials such as carpeting vinyl tile or othe...

Page 9: ...within a height of 15 ft above the meter regulator assembly I Clearance to service regulator vent outlet 36 910 mm 36 910 mm J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm for fi...

Page 10: ...epaint rated175 Forhigher ontheundersideofthemantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sides Refer to Table 5 for minimum clearance values For typical installations see Figure 2 on Page 8 Figure 6 Minimum Distance to Unprotected Side Wall Figure 5 Minimum Mantel Clearances INNOVATIVE HEARTH ...

Page 11: ...bers references in the follow ing steps for detailed procedures Step 1 Page 11 Construct the appliance framing Position the appliance within the framing and secure with nailing brackets Step 2 Page 13 Route gas supply line to the right side Step 3 Page 14 Install the vent system and exterior termination Step 4 Page 20 Field Wiring Connect 120 VAC electrical power to the appliance receptacle Step 5...

Page 12: ...del No A B C D E F G H J 40 in 50 5 8 39 1 4 45 25 3 8 34 37 5 8 33 1 8 29 3 8 34 3 4 mm 1286 997 1143 645 864 956 842 746 883 45 in 56 3 4 44 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 1 8 34 1 2 41 mm 1442 1440 1216 721 1019 1108 969 876 1042 Figure 8 Fireplace and Framing Specifications INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT6340TYN AND DRT6345TYN INSTALLATION INSTRUCTIONS FIREPLACE...

Page 13: ... 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing with Power Vent Termination 6 1 4 159 mm 19 5 8 498 mm Figure 10 Right Front Corner of Fireplace Framing Step 2 ROUTING GAS LINE Route a 1 2 13 mm gas line along the inside of the right side framing as shown in...

Page 14: ... s vent components with these appliances Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier Dégagement conforme aux codes d installation locaux et aux exigences du foumisseunde gaz Use only approved venting components See Approved Vent Components on Page 4 These fireplaces must be vented directly to the outside The vent system may not service...

Page 15: ...0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2 2 0 1 1 5 1 5 8 3 5 5 7 8 4 4 1 0 0 2 1 1 4 1 9 4 5 5 7 5 4 1 0 2 1 1 1 5 1 8 5 5 5 6 4 0 0 0 0 2 1 2 1 5 2 6 5 5 7 8 6 4 1 0 0 0 2 1 3 1 5 8 6 5 5 7 3 7 4 0 1 0 0 2 1 3 1 3 7 5 5 7 7 4 1 1 0 0 2 1 4 1 5 0 8 ...

Page 16: ...hepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninaccordancewiththerequire mentsshowninFigures16and17onPage17 To add another vent component to a length of ventrun alignthedimpledendovertheinclined channel end of the previously installed section adjusting the radial alignment until the four locking dimples are...

Page 17: ...re Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm per meter in a direction away from the fireplace Smaller rise per foot run ratios are acceptable down to at or near level Use a carpenter s level to measure from a constant surface and adjust the support...

Page 18: ...sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on Page 17 NOTE Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm per meter in a direction away from the fireplace Smaller rise per foot run ratios are...

Page 19: ...t Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 77 mm 1 26 mm Adaptor SV4 5RCH 10 1 2 267 mm The Power Vent termination has been designed to perform in a wide range of weather conditions Terminations meet or exceed industry standards Whenselectingthelocationoftermination do not place the term...

Page 20: ...ace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control compartment and cut to length before installing the terminals Install provided hardware on the ends of the cable Cable is not provided The provided crimp terminals are intended for use with stranded cable If us...

Page 21: ...fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 latest version or local codes Route 14 gage AWG grounded solid wire Romex or equally sized stranded cable e g SJOT from the fireplace to the newly installed junction box near the termination Ensure the cable is sa...

Page 22: ...replace cracked or broken glass with any materials other than those provided by the appliance manufacturer Theglassdoorofthisappliance must only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately Factory Wired Field Wired Junction Box Tab Intact Tab Intact n e e r G d n u o r G e t i h W l a r t u e N 120 VAC Black Gr...

Page 23: ...nes are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Step 7 INSTALL FIREBOX LINER KIT Traditional models Install the firebox liner kit per the included instructions Step 8 VERIFYING APPLIANCE OPERATION Turn on burner then observe the individual tongues of flame on the burner Make sure all ports are ...

Page 24: ...set was engineeredtogivetheapplianceasafe reliable and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very hot and will remain hot up to one hour after gas supply is turned off Handle only when logs are cool Turn off all electricity to the appliance before you i...

Page 25: ...s At The Bottom Of The Logs Over The Grate 4 3 Figure 37 Placing Logs 3 and 4 Align Groove At The Bottom Of Log 2 Over The Grate And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Tablex 12 Log Set Align Hole At Bottom Of Log 5 Over The Pin On Log 2 6 5 7 2 Figure 38 Placi...

Page 26: ...geover therailatthebottomofthefireboxopening 3 Swing the door up and back Ensure the gasketseatsevenlyasthedoordrawsshut Engage the nut insert and fasten with two screws to secure the door 4 Install the door modesty shield on top flange glass door as follows grab the door modesty shield with both hands with the open hem going down and engage it with the upper lip of the glass door frame by pushing...

Page 27: ...e operates properly finish the installation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if the air shutter is closed too much Any damage due to carboning resultingfromimproperlysetting the air shutter is not covered under the warranty Air Shutter Opening Burner Orifice G...

Page 28: ...OWED in the clearance zones around vent compo nents Keep this area free from combustible materials Figure 42 Finished Wall Insulation is NOT ALLOWED in the clearance zones around vent components Keep this area free from combustible materials Adaptor Plus 4 Feet Vertical Vent Min 90 Elbow 3 Min 77 mm Top of Appliance 10 3 8 Min 263 mm Combustible materials are allowed above this point on the face o...

Page 29: ...palement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces degraisseoud huile Collezl étiquettesurleboîtier de la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Si...

Page 30: ... 77L76 SV4 5E45 45 Degree Elbow 77L77 SV4 5E90 90 Degree Elbow H2246 SV4 5HF Firestop Spacer Horizontal 3 1 1 spacing 10 pack H2247 SV4 5VF Firestop Spacer Vertical 1 1 1 spacing 10 pack The following flashings come packaged with a storm collar H5816 SV4 5 TWSK Through Wall Shield Kit used to shield the direct vent pipe from blown insulation Ref instr 750247M 96K93 SV4 5SU Support Strap 96K92 SV4 ...

Page 31: ...fants ou les adultes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux ...

Page 32: ...foyer Figure A Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur le boîtier de la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 3 Si vous ne trouvez pas les étiquettes...

Page 33: ... of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper opera tion Never obstruct the front openings of the appliance Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con...

Page 34: ...es gas pressure requirements Test gauge connections are provided on the front of the gas control valve identified IN for the inlet and OUT for the manifold side see Figure 1 on Page 6 The control valve has a 3 8 10 mm NPT thread inlet and outlet side of the valve The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of tha...

Page 35: ...and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces AVERTISSEMENT Lesjeunesenfantsdevraientêtresurveillésétroitementlorsqu ilssetrou...

Page 36: ...ction The life span of the receiver batteries depends on various factors Quality of the batteries used Number of ignitions of the appliance etc When the receiver batteries are low no beep willbeemittedfromthereceiverwhenitreceives anON OFFcommandfromthetransmitter This is an alert for a low battery condition for the receiver When the batteries are replaced the beep will be emitted from the receive...

Page 37: ... are low or depleted the appliance can be turned on manually by sliding the ON REMOTE OFF slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on if the gas valve is in the ON position Transmission Set Point Temp Level State Flame On Child Safety Lock Out Low Battery Alarm Room Temperature Maximum Level Indicatiors Hot F...

Page 38: ...urn ON the appliance with the remote transmitter 1 ManuallyslidetheON REMOTE OFFswitch totheREMOTEposition thenpresstheON OFF key on the transmitter 2 Blower should start immediately 3 Igniter starts sparking and pilot will light 4 Burner should light after a few seconds To Turn OFF 1 ManuallyslidetheON REMOTE OFFswitch to the OFF position or press the ON OFF key on the transmitter 2 Burnerandpilo...

Page 39: ... stoppers This willensureaproperflameandsafecombustion Inspect Wiring Refer to wiring diagram on Page 46 CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing ATTENTION Aumomentdel entretien des commandes étiquetez tous les fils avant de les débrancher des erreurs de cáblage peuvent en...

Page 40: ...ngage it with the upper lip of the glass door frame by pushing it all the way down Make sure the installed shield is firmly in place WHEN INSTALLING THE GLASS DOOR SECURELY TIGHTEN THE LATCH SCREWS SEETHEFIRSTWARNINGONTHISPAGE Wheninstallingtheglassdoor ensurethe spacing on both sides are equal WARNING The door should easily close without needing to be pressed down If it has to be pressed down to ...

Page 41: ...nceandpreventsooting Whenpositionedproperly as shown twigs will be positioned between flame peaks and will not impinge any flames WARNING DO NOT attempt to install the logs until the appliance installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appliance a ...

Page 42: ...er The Grate And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 18 Log Set Align Hole At Bottom Of Log 5 Over The Pin On Log 2 6 5 7 2 Figure 59 Placing Logs 5 6 and 7 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Engage Log...

Page 43: ...used by incomplete combustionintheflamesandlackofcombustion air entering the air shutter opening To achieve a warm yellow orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are not impinging on any of the ...

Page 44: ...ust the flame move the adjustment air shutter located on the lower venturi back or forward to increase or reduce the air shutter opening respectively Position the air shut ter to the factory setting as shown in Table 20 Allow the burner to operate for at least 15 minutes Observe the flame continuously If it appearsweakorsootyaspreviouslydescribed adjusttheairshutteruntiltheflameappearance is as de...

Page 45: ...l Number_________________________________________________ Fireplace Serial Number__________________________________________________ Date Installed__________________________________________________________ Type of Gas Used in Fireplace_____________________________________________ Dealer Name __________________________________________________________ If you encounter any problems or have any questio...

Page 46: ...DANGEREUX Pilot Tube Spark Electrode Flame Sensor IPI Pilot 885 Valve Optional Split Flow BL W Y Y BR G O O R R B B G GR R B BL WH B B W G Battery Holder w Switch ON Remote OFF Battery Holder Wire Harness Reset Switch See instructions Power Vent Blower Power Vent Models Only Air Pressure Switch Power Vent Only Note On models without pressure switch these connectors are plugged together Main Wire H...

Page 47: ... 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE Bag of Platinum Embers Ceramic and Porcelain Firebox Liner Kits Model Cat No Model Description 40 in H8581 LKP BK MDLX40 Porcelain Black H2220 BLKH LSM40 Ceramic Buff Herringbone H4803 BLK REDH LSM40 Ceramic Red Herringbone H8697 LKC BFRS MDLX40 Ceramic Buff Rustic H8698 LKC RDRS MDLX40 Ceramic Red Rustic 45 in H8696 LKP B...

Page 48: ...he pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building OPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE Imme...

Page 49: ...10 Appuyez sur le bouton ON OFF pour sélectionner ON 11 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 12 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l admission de gaz de l appareil et appelez un technicien qualifié ou le fournisseur de gaz 1 Coupez l alimentation électrique de l appareil s il faut procéder à l entretien 2...

Page 50: ...he system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Glowing Embers Homeowner Qualified Service Technician Remove old ember materials rockwool and vacuum the ember placement area Place new embers per ...

Page 51: ...l a service technician The burner lights then immediately goes out Gas is not reaching the fireplace Check the gas supply and gas shutoff valves call a service technician if required Loose wires to the valve or ignition module Check the gas supply and gas shutoff valves call a service technician if required Pilot flame is not engulfing the sensor Call a service technician Obstructed vent system Ca...

Page 52: ...ot Flame Cover the Flame Rod Is the Sensor Wire in Good Condition Is There Continuity to Ground from the Pilot Burner No Replace Control Module Does Pressure Switch Open During Operation Yes No Replace Ignition Module Yes Is Vent Partially Blocked Is There Water Dirt in Hose to Pressure Switch Are Hose Connections Loose Is the Hose Cracked Replace Pressure Switch No Replace Control Module No Does ...

Page 53: ...Gas H7924 1 H8141 1 14 Orifice Propane Gas J8002 45 1 H2287 44 Traditional 1 15 Bag of Glowing Embers Traditional 88L53 1 88L53 1 16 Grate Assembly Traditional H4907 1 H4907 1 17 Gas Line Flexible Connection 93L32 1 93L32 1 18 Modesty Panel Right Side H3371 1 H3372 1 19 Modesty Panel Left Side H3373 1 H3374 1 20 Floor Panel H3369 1 H3370 1 21 Bag of Volcanic Stone Traditional 80L42 1 80L42 2 22 Ba...

Page 54: ...DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 29 15 21 22 7 17 13 12 6 8 11 9 5 1 4 16 3 20 19 18 31 30 14 REPLACEMENT PARTS INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT6340TYN AND DRT6345TYN INSTALLATION INSTRUCTIONS 10 fire parts com ...

Page 55: ... or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installation or app...

Page 56: ...tant information about your fireplace Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name 1769 East Lawrence Street Russellville AL 35654 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for firep...

Reviews: