![Super Circuits DVQ-2 User Manual Download Page 27](http://html.mh-extra.com/html/super-circuits/dvq-2/dvq-2_user-manual_1401722027.webp)
You can also up set up multi-detection areas.
Press
-
MINUS to set the entire area under motion detection.
Press
+
to disable motion detection for the entire area.
4) LS (Level of Sensitivity)
Use to set motion detection sensitivity. The smaller the value, the higher sensitivity for motion detection. The highest
sensitivity setting is 00, and the lowest sensitivity setting is 15. The default value is 07.
5) SS (Spatial Sensitivity)
Control the number of cells or boxes above that will be used to detect an object in motion. Example: Setting this
number to 3 will require an object size to be the same or larger than 3 cells to trigger the motion detection alarm. The
smaller the value is, the higher sensitivity for motion detection. The highest sensitivity setting is 00, and the lowest
sensitivity setting is 15. The default setting is 03.
Note:
The default setting of SS is 03. An object detected by 3 or more grids will trigger the motion
detection alarm and start recording or trigger external devices. The SS value must be less than the
number of grids that you set up for the motion detection area.
6) TS (Time of Sensitivity)
“TS” sensitivity detects how long one object stays in the detection area and triggers the recording. The smaller the
value is, the higher sensitivity for motion detection. The highest sensitivity setting is 00, and the lowest sensitivity
setting is 15. The default setting is 02.
7) RE (Reference)
“RE” is to set a reference for detection. The default value is 10, which means the DVR will compare 10 continuous
images at one time according to the sensitivity of LS, SS, TS simultaneously. The bigger the value is, the higher
sensitivity for motion detection. The highest sensitivity is 61.
8) ALARM
Select LOW to control ALARM INPUT pins 3 ~ 6 on external 15 pin connector. Use ALARM INPUTS to monitor
external motion detectors, Infrared sensors and other external devices. The default alarm value is OFF. Use LOW to
control pins 3~6, when pins 3 ~ 6 are grounded to 0 volts ALARM recording will trigger.
Note:
High/ Normally close - When the voltage is high (around 4V), the alarm is triggered.
Low/ Normally open - When the voltage is low (around 0V), the alarm is triggered.
(2.) Motion Detection Recording Time Duration
1) Go to Main
MENU> ADVANCE> ALERT> ALARM DURATION
(SEC)
Set the motion record time duration. Press “ENTER” or “+” / “-” buttons to set alarm recording duration seconds.
Options 5, 10, 20 or 40 seconds.
27