AVSI-12 Interview Room System Setup and User Guide
SECTION 3: SYSTEM SETUP
NOTE
Functions of the wires attached to the switch may change. Always wire the switch so that it functions as a Normally Open (N.O.)
switch.
CAB-ASK cable
to recorder
White and
green leads
(unused)
7.
Insulate the ends of the white lead and one green lead from the switch using electrical tape. Be certain that they are not
electrically connected together.
8.
Anchor the CAB-ASK cable to electrical box (if used) or to a wall to prevent it from being pulled away from the switch. Leave
a few inches of extra cable between the anchor and the switch for maintenance when needed.
9.
Mount the switch plate securely to a wall or electrical box, as determined earlier.
3.3 Connect the CAB-ASK cable to the recorder Alarm In termi-
nals
At the back panel of the recorder, do the following:
1.
Remove about 2” of insulating sheath from the end of the CAB-ASK cable.
2.
Strip 1/4” of insulation from both the red and black wires using a 22 gauge wire stripping tool.
3.
At the alarm terminations, push and hold in the orange button associated with the
ALARM IN 1
terminal, insert the CAB-
ASK cable
red
wire all the way in, and then release the orange button. Tug on the wire to ensure that is securely attached.