Our company use L-shaped mounting bracket as electrode mounting bracket. According to the
site necessity, fix the bracket with steel nails or expansion bolts at proper locations by pool.
2.5 Illustration and description of junction box :( Two kinds of link distributing system)
[
1
]
Two-wire distributing system
INPUT terminals
Terminal
No.
OUTPUT terminals
Terminals on
controller
Coaxial inner
1
Coaxial inner’s extending
wire for electrode
GLASS
Shield (forbidden)
2
Shield (forbidden)
------
Coaxial shield
3
Coaxial shield’s extending
wire for electrode
REF
Temperature probes
red wire
4
Red wire’s extending wire
for electrode
T/P
Temperature probes
green wire
5
Green wire’s extending wire
for electrode
GND
Alternative
6
、
7 Alternative
------
Note: 1. Our company’s extending wire for electrode material No. is 7202-F94009-BK
and 7202-RG-58
9