Features and How to set parameters
1.08
2017/7/13
Suntech International Ltd.
Confidential Document
4-5. Parameters for various features
In order to set these various parameters properly, read carefully the contents and <Example> along with <Note>
described in the bottom inside the table below. In setting a new device, the
‘SyncTrak’ will show you detailed
explanation on how to set parameters relating to these
‘Fields’.
HDR
DEV_ID
VER
PARKING_LOCK
SPEED_LIMIT
PWR_DN
CON_TYPE
ZIP
GROUP_SEND
MP_CHK
ANT_CHK
BAT_CHK
M_SENSOR
CALL
GEO_FENCE
DATA_LOG
Field
Marks
Value
Meaning
HDR
“ST300SVC”
Command type
DEV_ID
9 char.
Device ID
VER
“02”
Protocol Version
PARKING_LOCK
‘0’ or ‘1’
Parking lock enable (1) / disable (0):
If 1, the device periodically checks vehicle position under
parking status. When the vehicle goes off some boundary or
starts moving faster than the predefined velocity, the device
reports the Parking Lock Emergency.
SPEED_LIMIT
String
Km/h
Over speed limit:
If 0, the device does not check the over-speed.
If 1 and if the vehicle runs faster than the over predefined
value, the device reports an alert once.
PWR_DN
‘0’ ~ ‘2’
Power saving type:
0 : Disabled sleep and deep sleep service
1 : Enabled deep sleep
2 : Enabled sleep
CON_TYPE
‘0’ or ‘1’
Connection Type with Server:
0 = KEEP_CON
1 = KEEP_DISCON
Detail explanation is below.
ZIP
‘0’ or ‘1’
Use Zip
Disable (0) / Enable (1)
GROUP_SEND
‘0’ or ‘1’
Group Send for stored data:
0 : Disable
1 : Enable. One packet can include up to 5 reports.
The
‘Group Send’ function is explained below.
MP_CHK
‘0’ or ‘1’
Checking Main Power Disconnection:
Disable (0) / Enable (1)
ANT_CHK
‘0’ or ‘1’
GPS Antenna Connection Error Check:
Disable (0) / Enable (1)
BAT_CHK
‘0’ or ‘1’
Backup Battery Error Check:
Disable (0) / Enable (1)