![SunTech ST310U Operation Manual Download Page 15](http://html1.mh-extra.com/html/suntech/st310u/st310u_operation-manual_1400858015.webp)
Doc. Title
Author
Page of Pages
ST310U OPERATION MANUAL
JH KIM
15 of 66
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.08
2017/7/13
Suntech International Ltd.
Confidential Document
PULSE2_OFF
This device does not have OUTPUT2
IN4_TYPE
This device does not have INPUT4
IN5_TYPE
This device does not have INPUT5
IN4_CHAT
This device does not have INPUT4
IN5_CHAT
This device does not have INPUT5
BAUD
This device does not have RS232.
<Example>
[command] ST300EVT;100850000;02;1;60;0;3;2;2;30;20;20;1;0;1;0;0;0;0;0;0;0;0;0;0;0;0
[response] ST300EVT;Res;100850000;010;1;60;0;3;2;2;30;20;20;1;0;1;0;0;0;0;0;0;0;0;0;0;0;0
<Note>:
** If IGNITION is set to ‘0’, the device doesn’t check driving or parking state of the vehicle. It always reports
status string under parking mode, and cannot support Parking Lock and the Service which enters Sleep or Deep
Sleep automatically when the vehicle is parked.
** If IGNITION is set to
‘2’, the device checks driving or parking state of the vehicle with voltage range of
vehicle
’s battery. We named it as ‘Virtual Ignition’. Virtual ignition runs when the device installed on a real
vehicle and it may need to adjust the voltage range for special vehicle. For setting method, please refer to 6.3 of
this document.
**
“IGNITION” should be selected to “Not Use Ignition” if “IN1_TYPE” = 12.
** In case of pulse, pulse time may have tolerance about dozens of ms.