10
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
TECHNICAL CHARACTERISTICS
Temperature range – regulation
:
0°C÷90°C, limit: 90°C÷110°C
Tolerance – regulation
: ± 5k, limit - 15k; -
6k (depends on the type)
Temperature differential – regulation
: 6
± 2k; 4 ± 1k (depends on the type), limit 25
± 8k; 15 ± 8k (depends on the type)
Automatic adjustment (TLSC/A) and
manual adjustment (TLSC).
Degree of protection = IP 40
.
Insulation class = I
.
Temperature change rate ≤ 1K/min
.
Maximal temperature point = 80°C
.
Maximal temperature for electric lamp =
125°C
Accumulation temperature = 15°C ÷ 55°C
.
Maximum pressure of the cartridge = 10
bar.
Constant time ≤ 1';.
Electric connection:
C-1 ADJ.: 10(2,5)A/250V~;
C-2 ADJ.: 6(2,5)A/250V~;
C-1 LIM.: 0,5A/250V~;
C2 LIM.: 10(2,5)A/250V~;
2.5. Thermostat /option/.
schema 1
This is an adjustable double THERMOSTAT
which is designed to regulate the water
temperature and ensures safety tolerance;
it can be manually adjusted (TLSC model)
or automatically adjusted (TLSC/A model).
CONFORMITY WITH STANDARDS
This product is in conformity with:
- EN 60730 - 1 and subsequent editions;
- EN 60730 - 2 - 9
CONFORMITY WITH REGULATIONS
This product complies with:
- Low Voltage Directive 73/23 EEC
- Electromagnetic Compatibility Directive
89/336/EC
Summary of Contents for P 1500
Page 2: ...2 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL ...
Page 8: ...8 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL CONNECTIONS SCHEMES ...
Page 9: ...9 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Page 13: ...13 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Page 36: ...36 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL 8 SHEMES t 65 C ...
Page 37: ...37 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Page 38: ...38 INSTALLATION and OPERATION MANUALINSTALLATION and OPERATION MANUAL ...
Page 43: ...INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ...
Page 44: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg ...