On the Thermoregulator:
-
Switch OFF the power supply (230 Vac)
-
Switch ON the Power Supply pressing at the same time one button on the
Remote Control waiting about 5 seconds until an acoustic signal is emitted
confirming the code learned.
6.6. User Menu (2)
Push contemporary buttons
P2
and
P4
for 3 (three) seconds to enter User Menu (2).
- To scroll the Menu push buttons
P3
or
P4.
-
To enter in a submenu push button
P2.
-
To modify the blinking value push button P3 (to increase) or P4 (to decrease).
-
To exit push button
P1.
6.6.1. Thermostats
Room Thermostat / Function Buffer
Thermostat
It allows to set the Room Thermostat value
P26=0
and
A19 =1
Or Function Buffer Thermostat
P26=1
Room Thermost at
Buff er Thermos tat
6.6.2. Chrono
Allows to program the ignitions/extinguishing
of the system
-1- Enable
It enables the Programming set.
Push button
P2
to enter.
Push buttons
P3/P4
for select.
ON
= enable programming set
OFF
= disable programming set.
Push button P
2
to confirm, or push
P1
to exit.
-2-
Program
It allows to schedule the 3 time bands
available for every day of the week.