Installer / Service Manual BURNiT PM Comfort
Plus
7 –ЕN
Working pressure Bar
2
2
Average fuel consumption per hour h/kg
1.5
3
Burn time of full pellet hopper at max.power h
8
12
CO content calculated to 13% O2 in the flue gas
at nominal heat output
0,02%
0,02%
Efficiency
%
87.5
91.2
Electrical power W
150
150
Supply voltage V/Hz
230/50
230/50
Recommended fuel
Wood-pellets 6-8 mm,
EN 14961-2:2011
The values in the table above are presented on a test base, performed by burning
wooden pellets with calorific values 18220 Kj/kg (equal to 4350 Kcal/kg).
All the data above is informative and not obligatory. The manufacturer reserves his
rights to change the data at any time aiming to improve the efficiency of the pellet
stove.
3.
Installation
3.1. General rules
Correct mounting and connection of exhaust gas system is extremely important for
safety use of pellet stove.
Any mistakes done during the installation are not covered by the MANUFACTURER.
It is obligatory the installation, the first start and the maintenance of the pellet
stove to be performed by an authorized installer/service BURNiT!
Recommendations BEFORE installing the pellet stove:
•
Check the minimum volume of the room where the pellet stove is to be installed
(should be no less than 40 m
3
);
•
Make sure there are holes for fresh air;
•
Follow all the norms/standards – technical, safety and constructional;
•
The proper functionality of the exhaust gases system (chimney reliability);
•
It is not permitted the installation of the pellet stove to be performed in bedrooms,
bathrooms as well as rooms which already had another heating unit installed without
enough access of fresh air (another stove, gas heater etc.)
•
There should not be any flammable substances in the room where the installation
will be done.
•
The space around the pellet stove should be built with stones, cement or any other
fireproof material.