Installer / Service Manual BURNiT PM Comfort
Plus
28 –ЕN
passage to
P25=0
in case of
no signal Encoder: alarm
Er07
6.7.3. Thermostat`s Menu
TP O4
Code
Description
Probe
Min.
Max.
U
13kW 25kW
Th01
Stove OFF Thermostat
Exhausting
5
900
[°C]
50
50
Th02
Deactivation Igniter
Resistance Thermostat
Exhausting
5
900
[°C]
52
52
Th03
Pre-Extinguishing
Thermostat for no flame
Exhausting
5
900
[°C]
50
50
Th06
Thermostat to go in
Stabilization from Variable
phase
Exhausting
5
900
[°C]
52
52
Th07
Modulation Thermostat for
Exhausting
OverTemperature
Exhausting
5
900
[°C]
230
250
Th08
Safety Thermostat for
Exhausting
OverTemperature
Exhausting
5
900
[°C]
250
270
Th09
Ignition Bypass Thermostat
Exhausting
5
900
[°C]
250
250
Th18
Antifreeze Thermostat
Stove
5
10
[°C]
5
5
Th19
Enable Pump Thermostat
Stove
30
85
[°C]
55
55
Ih19
Enable Pump Thermostat
Hysteresis
Stove
1
20
[°C]
2
2
Th21
Discharge Thermostat
(Unblock Pump)
Stove
30
85
[°C]
80
80
Ih24
Stove Thermostat Hysteresis
Stove
1
20
[°C]
2
2
Th25
Stove Safety Thermostat
Stove
80
99
[°C]
85
85
Th26
Minimum Range of Stove
Thermostat
Stove
30
60
[°C]
35
35
Th27
Maximum Range of Stove
Thermostat
Stove
60
95
[°C]
80
80
Th28
Stove OFF Thermostat in
Standby
Exhausting
5
900
[°C]
100
100
Ih33
Room Thermostat Hysteresis
Room
0
10
[°C]
2
2
Th47
[Stove Probe – Buffer Probe]
Differential Thermostat
Buffer
1
30
[°C]
5
5
Ih47
Differential Thermostat
Hysteresis
Buffer
1
5
[°C]
1
1
Ih48
Buffer Thermostat
Buffer
1
20
[°C]
2
2