9.3.8. Suspend Time
In this menu you
can adjust the time
period for which
the burner will
remain in
suspended mode and the time can be set
in minutes with a maximum duration of
180
minutes.
If within a set time (
20
minutes)
the temperature in the boiler does
not decrease, the burner enters into
Extinguish mode
– crossed-out flame
.
9.3.9. Cleaning set up in working mode
In menu Interm.
Cleaing
self-
cleaning for the
burner can be set.
The main burner's
fan turns on during certain cycle on
higher power level for certain period of
time. All parameters can be changed.
9.3.10.
From this menu
you activate the
operation of the
s e l f - c l e a n i n g
system during the
intermediate cleaning
9.4. Auto Clean Setup
You can set time
and number of
engagements
of
the burner self-
cleaning system.
It is mandatory to have at least one self-
cleaning session in
24 hours
.
Maximum number of self-cleaning
sessions in 24 hours – twelve.
Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page of
the menu.
9.5 Hardware Setup
Use this submenu
to activate (with
check mark) or
d e a c t i v a t e
a d d i t i o n a l
peripherals.
CH PUMP
– central heating pump
DHW PUMP
– domestic hot water pump
Thermostat
.
Select the desired option using the
navigation arrows. Use the „
Enter
”
button to open the next parameter. Use
the
button to open the next page
of the menu.
From this screen
menu you can
choose the boiler
o p e r a t i o n
m a n a g e m e n t
mode. This menu is valid only in the
event of
"CH only"
option selected. By
selecting the checkmark
"Buffer"
the
boiler will be controlled according to
temperature inside the buffer tank
connected to the boiler. The setting of
the temperature of the buffer tank
circulation pump start and stop
temperatures is done as described above.
When selecting the boiler management
via thermostat option the boiler will be
controlled by the signal input from the
thermostat, whereas the options are:
thermostat normally open or thermostat