ECCO SG04LP1 | User Manual
11
3. TECHNICAL SPECIFICATIONS
Model
SUN-3.6K-
SG05LP1-EU
SUN-5K-
SG05LP1-EU
SUN-6K-
SG05LP1-EU
SUN-7.6K-
SG05LP1-EU
SUN-8K-
SG05LP1-EU
Battery Input Data
Battery Type
Lead-acid or Lithium-ion
Battery Voltage Range
40~60V
Max. Charging Current
90A
120A
135A
190A
190A
Max. Discharging Current
90A
120A
135A
190A
190A
Charging Curve
3 Stages/Equalisation
External Temperature
Sensor
Yes
Charging Strategy for Li-Ion
Battery
Self-Adaptation to BMS
PV String Input Data
Max. DC Input Power
4680W
6500W
7800W
9880W
10400W
PV Input Voltage
370V (125V~500V)
MPPT Range
150~425V
Start-up Voltage
125V
Full Load DC Voltage Range
300~425V
200~425V
PV Input Current
13A+13A
26A+26A
Max. PV Isc
17A+17A
34A+34A
No. of MPPT / Strings Per
MPPT
2/1+1
AC Output Data
Rated AC Output and UPS
Power
3600W
5000W
6000W
7600W
8000W
Max. AC Power
3690W
5500W
6600W
8360W
8800W
Peak Power (off-grid)
2 times of rated power, 10 S
AC Output Rated Current
16.4A
22.7A
27.3A
34.5A
36.4A
Max AC Current
18A
25A
30A
38A
40A
Max Continuous AC
Passthrough
35A
30A
50A
Output Frequency and
Voltage
50/60Hz; L/N/PE 220/230Vac (single phase)
Grid Type
Single-Phase
Current Harmonic Distor-
tion
THD<3%(Linear load<1.5%)
Efficiency
Max. Efficiency
97.60%
MPPT Efficiency
97.00%
Euro Efficiency
99.90%
Protection
Integrated
PV Input Lightning Protection, Anti-islanding Protection, PV String Input
Reverse Polarity Protection,Insulation Resistor Detection, Residual Current
Monitoring Unit, Output Over Current Protection,Surge protection
Summary of Contents for ECCO SUN-3.6K-SG05LP1-EU
Page 9: ...ECCO SG04LP1 User Manual 9 2 1 Product Size ...
Page 17: ...ECCO SG04LP1 User Manual 17 4 5 Function Port Definition ...
Page 21: ...ECCO SG04LP1 User Manual 21 ...
Page 23: ...ECCO SG04LP1 User Manual 23 4 9 1 Recommended AC Surge Protector ...
Page 26: ...ECCO SG04LP1 User Manual 26 4 12 Meter Connection 4 12 1 System Connection for the CHNT Meter ...
Page 27: ...ECCO SG04LP1 User Manual 27 4 13 Wiring System for Inverter ...
Page 30: ...ECCO SG04LP1 User Manual 30 4 16 Single Phase Parallel Connection Diagram 03 02 01 ...
Page 31: ...ECCO SG04LP1 User Manual 31 4 17 Three Phase Parallel Inverter 03 02 01 ...
Page 32: ...ECCO SG04LP1 User Manual 32 4 18 Typical Application Diagram of Diesel Generator ...
Page 63: ...ECCO SG04LP1 User Manual 63 6 OPERATING MODES 6 1 Mode I Basic 6 2 Mode II With Generator ...
Page 64: ...ECCO SG04LP1 User Manual 64 6 3 Mode III With Smart Load 6 4 Mode IV AC Couple ...
Page 65: ...ECCO SG04LP1 User Manual 65 ...
Page 71: ...Ltd wered by Po ...