Installation and Operation Manual
SA-07-11-87, Rev A
24
January 2019
Disassembly (All Configurations)
1.01 Remove the (6) seal housing nuts
located closest to the inlet and
discharge as shown. Place two lifting
brackets over each of the studs (each
bracket is unique, and must go on the
correct side). Correct locations will
have the brackets parallel to the pump
case flange faces. Bolt the lifting
brackets to the seal housing using (2)
bolts per side finger tight. DO NOT
TIGHTEN THE LIFTING BRACKET
BOLTS YET.
Note:
Motor/Cartridge Seal Housing /
Cartridge Seal Removed for
clarity.
1.02 Install the Lifting Hanger using (2)
bolts/nuts per side. Tighten each size.
With the Lifting Hanger securely
bolted to the Lifting Brackets, tighten
the Lifting Bracket bolts into the seal
housing.
NOTE:
Motor/Cartridge Seal Housing/
Cartridge Seal removed for
clarity.
1.03 (Not applicable to the Bearing Box
configuration)
Bolt the extended shaft motor to the
lifting hanger using the motor’s
integrated lifting feature holes (this
may require removal of the motor’s
“lifting ears”). Note that these bolts
will NOT take any vertical load and
are merely intended for anti-rotation
of the motor assembly.