Instruction and Operation Manual
19
MAINTENANCE
Disassembly of LMV-313
STEP 1
Remove the nuts from the pump casing
studs. Lift the gearbox and seal housing up
off of the pump casing. Remove o-rings 936B
and 936CB and backing ring 70B.
When lifting, if the pump case and seal housing
are difficult to separate, use the three jacking
screws to break the seal.
STEP 2
Install the anti-rotation device to prevent
impeller from spinning.
Note: Locking tools, part number TO01AK03
for splined or TO01AK02 for coupled
shafts, are available for purchase from
Sundyne Corporation.
STEP 3
Remove the inducer.
Note
: All inducers have a left-handed thread
.
Note: When working on a pump with a
tapered inducer, the inducer must be
removed before the diffuser can be
removed from the seal housing.
Summary of Contents for LMV-313
Page 1: ...SUNDYNE LMV 313 PUMPS Instruction and Operation Manual August 2007 ...
Page 36: ...Instruction and Operation Manual 32 Figure 15 Inducer Housing Shim Adjustment ...
Page 40: ...Instruction and Operation Manual 36 Figure 17 Service Check Points ...
Page 69: ...Instruction and Operation Manual 65 Figure 22 Gearbox Components ...
Page 70: ...Instruction and Operation Manual 66 Figure 23 Pump Nomenclature ...
Page 71: ...Instruction and Operation Manual 67 Figure 24 Exploded View ...
Page 72: ...Instruction and Operation Manual 68 Shaft Assemblies Figure 25 Shaft Assemblies ...