Instruction and Operation Manual
3
TRANSPORT AND STORAGE
Inspection
Immediately inspect your Sundyne product upon
receipt of the equipment. Check for any
damage, which may have occurred during
shipment. Notify the carrier and Sundyne
immediately if damage is evident.
Note: The input shaft on the pump may not
turn freely due to seal drag and speed
increasing gear meshes. If the input
shaft does turn freely, and if rotation is
“not smooth,” damage may have
occurred during shipping.
Storing Your Pump Short-Term
If your Sundyne pump is not to be installed
immediately, protect it from exposure to
moisture and dust. Do not remove the factory
installed shipping covers for casing flanges and
seal ports. Ensure that the shipping covers be
kept securely in place.
Note: Observe the storage instructions
provided by the driver manufacturer.
Storing Your Pump Long-Term
In addition to the precautions in the short-term
section above, additional precautions are
required for long-term storage.
If your Sundyne pump will not be operated for a
period of time exceeding six months from the
date of shipment, long-term storage conditions
must be met to ensure minimum corrosion
damage to components.
Note: Sundyne does not accept liability for
equipment damaged during the storage
period. Sundyne does not guarantee
the quality of equipment during and
after the storage period.
To ensure the original quality of the Sundyne
pump after storage, all components must be
inspected by an authorized Sundyne service
engineer. Components that are not
manufactured by Sundyne (except mechanical
seals) must be inspected by its own
manufacturer.
Note: Any inspection fees are the sole
responsibility of the purchaser.
Factors, which affect the quality of a Sundyne
pump, when stored, are:
•
Humidity
•
Temperature
•
Surrounding
chemicals
Long-term storage methods must prevent
damaging conditions from making contact with
the internal components of the equipment. When
the equipment is stored in strong chemical
environments or near salt water, protection must
occur immediately upon receipt of the
equipment.
Recommended Long-Term Storage
Procedures
Sundyne recommends that you do the following
to prevent damage to your pump during long-
term storage:
1. Store your pump only in an indoor, climate-
controlled building. These conditions will
maintain constant temperature and humidity.
2. Perform inert gas purging of component
internals.
Summary of Contents for LMV-313
Page 1: ...SUNDYNE LMV 313 PUMPS Instruction and Operation Manual August 2007 ...
Page 36: ...Instruction and Operation Manual 32 Figure 15 Inducer Housing Shim Adjustment ...
Page 40: ...Instruction and Operation Manual 36 Figure 17 Service Check Points ...
Page 69: ...Instruction and Operation Manual 65 Figure 22 Gearbox Components ...
Page 70: ...Instruction and Operation Manual 66 Figure 23 Pump Nomenclature ...
Page 71: ...Instruction and Operation Manual 67 Figure 24 Exploded View ...
Page 72: ...Instruction and Operation Manual 68 Shaft Assemblies Figure 25 Shaft Assemblies ...