Instruction and Operation Manual
10
SundGard
®
Oil Filter
The specially designed oil filter is rated for 3
microns at a beta ratio of 200.
Note: Oil filters other than Sundgard
®
-OEM
filters will void the Sundyne warranty.
The gearbox oil and filter should be changed
every six months. Refer to the Lube Oil
Specifications in the Specification section of this
manual for more information.
Main Lube Pump and Lube Oil Priming Kit
Note: Use the auxiliary lube oil priming pump
to circulate oil around the heater when
the main drive motor is not running.
The main lube pump is a positive displacement
gear type pump directly driven by the input shaft.
A pre-lube system is required on some pumps.
The kit consists of:
•
Motor driven positive displacement pump
•
Check
valve
•
Gages
•
Necessary
piping
To start the pump, allow the pre-lube pump to
run for approximately 30 seconds. There should
be a minimum indication of 7 psig (0.5kg/cm
2
)
maintained for 30 seconds before starting the
main driver. If the oil piping has been drained,
allow several minutes of operation to bleed
trapped air from the system.
Note: Only allow shut down of pre-lube pump
after main driver is at full operating
speed.
Figure 7. Lube Oil Schematic
Summary of Contents for LMV-313
Page 1: ...SUNDYNE LMV 313 PUMPS Instruction and Operation Manual August 2007 ...
Page 36: ...Instruction and Operation Manual 32 Figure 15 Inducer Housing Shim Adjustment ...
Page 40: ...Instruction and Operation Manual 36 Figure 17 Service Check Points ...
Page 69: ...Instruction and Operation Manual 65 Figure 22 Gearbox Components ...
Page 70: ...Instruction and Operation Manual 66 Figure 23 Pump Nomenclature ...
Page 71: ...Instruction and Operation Manual 67 Figure 24 Exploded View ...
Page 72: ...Instruction and Operation Manual 68 Shaft Assemblies Figure 25 Shaft Assemblies ...