![background image](http://html.mh-extra.com/html/sunbeam/snb652sia-series/snb652sia-series_service-manual_1393662024.webp)
Description of all Functions
Water drainage
WATER DRAINAGE
LUX
ECO - STANDARD
F3
3 BEEPS
X
X
X
X
X
X
3 BEEPS
During emptying, if 2 minutes have passed since the drain pump was started and the
water level micro has not deactivated, the machine will stop and beep as follows:
3 beeps
Pause 4”
3 beeps
pause 4”………and so on
This means error code F3.
Possible causes:
1. IF IT REALLY DOESN’T EMPTY:
-
Faulty
pump
.
-
Pump
blocked.
-
Drainage
pipe
blocked.
-
Water
return
- Pump not connected to mains power (Current).
2. IF IT REALLY EMPTIES:
- Mechanical system for water level faulty (locked).
- Level micro faulty (Short-circuited).
-
Faulty
installation.
-
Faulty
card.