2
Sun Blade T6320 Server Module Installation Guide • April 2010
Physical Specifications
The Sun Blade T6320 server module is approximately 12.9 x 20.1 x 1.7 inches in a 1U
form factor. The server module plugs in to a Sun Blade modular system, or
chassis
,
which provides power to each module, as well as cooling through fans. In addition
to the main power, the chassis provides AUX power to each module to power the
local FRU ID EEPROM. This AUX power enables the chassis management module
(CMM) to query each module slot prior to main power and fan application to
validate that there is sufficient power and cooling to support the number and type of
modules installed in the chassis.
Environmental Requirements
includes the environmental requirements that are specific to the Sun Blade
T6320 server module.
TABLE 1-1
Sun Blade T6320
Server Module Environmental Requirements
Condition
Requirement
Operating temperature
5˚C to 35˚C noncondensing
Nonoperating temperature
-40˚C to 65˚C
Operating humidity
10% to 90% noncondensing (27˚C max. wet bulb)
Nonoperating humidity
93% noncondensing (38˚ C max. wet bulb)
Operating altitude
3048 meters at 35˚C
Nonoperating altitude
12,000 meters