![Sun Microsystems Sun StorEdge T3 Installation, Operation And Service Manual Download Page 89](http://html.mh-extra.com/html/sun-microsystems/sun-storedge-t3/sun-storedge-t3_installation-operation-and-service-manual_1393010089.webp)
Chapter 3
Operation
3-5
3.2.2.1
RAID 0
Data blocks in a RAID 0 volume are striped across all the drives in the volume in
order. There is no parity data, so RAID 0 uses the full capacity of the drives. There is
no redundancy, however; if a single drive fails, all data on the volume is lost.
shows the data layout in a RAID 0 volume.
3.2.2.2
RAID 1
Each data block in a RAID 1 (1+0) volume is mirrored on two drives, and the blocks
are striped across all the drives in the volume. If one of the mirrored pair fails, the
data from the other drive is used. Because the data is mirrored in a RAID 1
configuration, the volume has only half the capacity of the assigned drives. For
example, if you create a four-drive RAID 1 volume with 18-Gbyte drives, the
resulting data capacity is 2 x 18 = 36 Gbytes.
shows the data blocks in a
RAID 1 (1+0) volume with 9 drives.
3.2.2.3
RAID 5
In RAID level 5, data is striped across the drives in the volumes in segments, with
parity information striped across the drives as well. Because of this parity, if a single
drive fails, data can be recovered from the remaining drives. Two drive failures
cause all data to be lost. A RAID 5 volume has the data capacity of all the drives in
the logical unit less one. For example, a 5-drive RAID 5 volume with 18-Gbyte drives
TABLE 3-2
RAID 0 Data Blocks
1
1. Block numbers are written in hexadecimal notation.
Stripe
Drive1
Drive2
Drive3
Drive4
Drive5
Drive6
Drive7
Drive8
Drive9
0
0
1
2
3
4
5
6
7
8
1
9
A
B
C
D
E
F
10
11
2
12
13
14
15
16
17
18
19
1A
TABLE 3-3
RAID 1
(1+0)
Data Blocks
1
1. Block numbers are written in hexadecimal notation.
Stripe
Drive1
Drive2
Drive3
Drive4
Drive5
Drive6
Drive7
Drive8
Drive9
0
0
1
2
3
4
5
6
7
8
1
1
2
3
4
5
6
7
8
0
2
9
A
B
C
D
E
F
10
11
Summary of Contents for Sun StorEdge T3
Page 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...