A-2
Sun StorEdge T3 Disk Tray Installation, Operation, and Service Manual • July 2000
A.2
Environmental Specifications
TABLE 1
Environmental Specifications
Specifications
Operating
Nonoperating
Notes
Temperature
5C to 35C with
maximum gradient
20C per hour
-20C to 60C with maximum
gradient 20C per hour
Relative humidity
20 to 80%
noncondensing with
maximum gradient
10% per hour
5 to 93% noncondensing with
maximum gradient 10% per
hour
Effective altitude
(from drive
specification)
–1,000 to +10,000 feet
(-305 to +3,048
meters)
-1,000 to +40,000 feet (-305 to
+12,192 meters)
Shock (from drive
specification)
4g for maximum
duration of 11 ms
(half sinewave)
10g for maximum duration of
11 ms (half sinewave)
Shock can
be applied
from any
axis X,Y,Z
Vibration (from
drive specification)
5 to 500 Hz @ 0.25g
(swept sinewave)
5 to 500 Hz @ 1.0g
(swept sinewave)
Vibration
can be
applied
from any
axis X,Y,Z
Summary of Contents for Sun StorEdge T3
Page 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...